Revised 07.01.2020

 

BELT REPLACEMENT INSTRUCTIONS

 

1.

 

REMOVE ACCESS PANEL

 

2.

 

LOOSEN JAM NUT ON REVERSE TENSION BOLT

 

3.

 

TURN REVERSE TENSION BOLT INWARDS TO ALLOW 

 

TENSIONER TO MOVE

 

4.

 

MOVE/PUSH TENSIONER PULLEY AWAY FROM BELT AND 

 

REMOVE BELT

 

5.

 

INSTALL BELT IN REVERSE ORDER, MAKE SURE BELT IS 
ALIGNED PROPERLY AND ALL GROOVES ARE IN THE 

 

CORRECT AREA

 

6.

 

ADJUST REVERSE TENSION BOLT SO THERE IS 

1/16”

-

1/8” 

CLEARANCE BETWEEN BOLT AND THE BODY OF THE UNIT. 

 

Содержание MODULE-AIR AF-31243 Series

Страница 1: ...t air filtration where airborne particles are prevalent The air cleaner consists of 12 intakes and two exhausts two motors two blowers electrical components and a riveted sheet metal housing These uni...

Страница 2: ...alled using the above instructions your AF 31243 air cleaner s can be operated with the flip of a switch Because the AF 31243 series is designed as an Air quality Maintenance system it is important th...

Страница 3: ...like aluminum magnesium and other materials NFPA also has standards that cover other dusts like grain and plastics ect For guidelines on determining which precautions should be taken please refer to...

Страница 4: ...shall be held liable for direct or consequential damages resulting from improper methods structural failure or inadequate supports Installation Diagram on PG 5 Installation methods will depend upon th...

Страница 5: ...5 Tanis Technologies 31243 Filtration Unit Revised 07 01 2020 Simple Installation Guide For a more detailed description see page 4...

Страница 6: ...6 Tanis Technologies 31243 Filtration Unit Revised 07 01 2020 NOTE EACH UNIT CONTAINS 2 MOTORS THAT EACH NEED TO BE WIRED SEPARATELY...

Страница 7: ...7 Tanis Technologies 31243 Filtration Unit Revised 07 01 2020...

Страница 8: ...8 Tanis Technologies 31243 Filtration Unit Revised 07 01 2020...

Страница 9: ...TENSION BOLT 3 TURN REVERSE TENSION BOLT INWARDS TO ALLOW TENSIONER TO MOVE 4 MOVE PUSH TENSIONER PULLEY AWAY FROM BELT AND REMOVE BELT 5 INSTALL BELT IN REVERSE ORDER MAKE SURE BELT IS ALIGNED PROPER...

Страница 10: ...ined to be defective in material or workmanship can be shipped prepaid to TANIS TECHNOLOGIES or authorized service facility in which case a determination will be made whether to repair or replace the...

Отзывы: