Troubleshooting Chart

 

Symptom

 

Possible Cause(s)

 

Corrective Action

 

Excessive belt noise

 

1. Belt is misaligned

 

1. Remove access panel.  Follow instructions on page 9 to ad-
just belt placement.  

 For further instruction, visit our website 

(TanisTechnologies.com) for belt adjustment video.

 

2. Belt is worn out, broken, or defective.

 

1. Remove back panel. Follow instructions on page 9 to replace 
belt.  

 For further instruction, visit our website 

(TanisTechnologies.com) for belt adjustment video.

 

Air cleaner has poor perfor-
mance.

 

1. It

s possible that the air cleaner may 

have been wired backwards upon instal-
lation.  Air will blow out the exhaust 
either way, but if wired correctly it 
should blow at about 58 mph.

 

1. If the motor is wired to run the wrong direction, disconnect 
power supply, & switch the necessary wires around to reverse 
the motors rotation with the voltage you are using.

 

2.  The bag filter may not be seated 
properly

 

2. Reach in each pocket to make sure fabric is not between 
filter stop and filter frame.

 

Air is not staying as clear as 
usual

 

1. Prefilters may be loaded with debris

 

1. Turn unit off, lock out power to unit, then replace the prefil-
ter by pushing clips out of the way and then sliding it out and 
sliding a new one in.

 

2. Bag filter(s) may be spent

 

2. Follow step (1) to remove the prefilter, then if unit is 
equipped with clips, push them out and away from the bag 
filter, slide out the old bag filter and slide in new one until clips 
snap around it.

 

Operation

 

Once installed using the above instructions, your AF

-

31243 air cleaner(s) can be operated with the flip of a 

switch. Because the AF

-

31243 series is designed as an 

Air quality Maintenance

” 

system, it is important that 

the units are turned on in the beginning of the shift and left on until the end of the shift. The reason the 
units need to remain on is because Air Cleaners train the air current throughout the entire area in order to 
ensure that all of the air is cycling through the filters. The process of training the air can take a while, but is 
usually about 30 minutes.

 

 

Maintenance

 

Follow these precautions when performing maintenance on the motor or blower. 

 

Turn off motor, and LOCK OUT electrical service to the unit.

 

LOCK OUT even when changing filters.

 

Change filters regularly to maintain optimum performance. If the performance of your air cleaners appears 
to be declining, try replacing the filters.

 

Be sure that replacement filters are always rated for the correct CFM and air flow.

 

 

NOTE FOR INSTALLING BAG FILTERS: 

 

When installing fiberglass bag filters, MAKE SURE THAT NO FABRIC IS PINCHED BETWEEN THE HEADER 
AND FILTER FRAME.  

Performance will decrease dramatically if bag filters are not properly installed.  To 

ensure no fabric is pinched, place your fingers inside each cell, and gently move each bag cell side to side, 
freeing any fabric sandwiched between the header and filter frame.

  

 

 

If the system requires maintenance exceeding filter change, read below

 

Take the unit down and place it on a level surface that allows access to the access panels on each side of the 
Main Housing. 

To access the motor, pulleys and belt:

 Remove the door panel by removing (12) ¼

-

20x1

-

1/4

” 

bolts from either the right or left access panel with a 3/8 socket.

 

Содержание MODULE-AIR AF-31243 Series

Страница 1: ...t air filtration where airborne particles are prevalent The air cleaner consists of 12 intakes and two exhausts two motors two blowers electrical components and a riveted sheet metal housing These uni...

Страница 2: ...alled using the above instructions your AF 31243 air cleaner s can be operated with the flip of a switch Because the AF 31243 series is designed as an Air quality Maintenance system it is important th...

Страница 3: ...like aluminum magnesium and other materials NFPA also has standards that cover other dusts like grain and plastics ect For guidelines on determining which precautions should be taken please refer to...

Страница 4: ...shall be held liable for direct or consequential damages resulting from improper methods structural failure or inadequate supports Installation Diagram on PG 5 Installation methods will depend upon th...

Страница 5: ...5 Tanis Technologies 31243 Filtration Unit Revised 07 01 2020 Simple Installation Guide For a more detailed description see page 4...

Страница 6: ...6 Tanis Technologies 31243 Filtration Unit Revised 07 01 2020 NOTE EACH UNIT CONTAINS 2 MOTORS THAT EACH NEED TO BE WIRED SEPARATELY...

Страница 7: ...7 Tanis Technologies 31243 Filtration Unit Revised 07 01 2020...

Страница 8: ...8 Tanis Technologies 31243 Filtration Unit Revised 07 01 2020...

Страница 9: ...TENSION BOLT 3 TURN REVERSE TENSION BOLT INWARDS TO ALLOW TENSIONER TO MOVE 4 MOVE PUSH TENSIONER PULLEY AWAY FROM BELT AND REMOVE BELT 5 INSTALL BELT IN REVERSE ORDER MAKE SURE BELT IS ALIGNED PROPER...

Страница 10: ...ined to be defective in material or workmanship can be shipped prepaid to TANIS TECHNOLOGIES or authorized service facility in which case a determination will be made whether to repair or replace the...

Отзывы: