Tandberg Data M-Series Installation Guide
Document T6423046-02 A01
February 2004
Disabling Unused Drive Bays
51
2
Press
Config
.
The GUI displays the
Configuration
screen (see
).
Figure 50
Configuration Screen
3
Press the
Up
or
Down
buttons until the drive ID for the unused drive bay
is highlighted.
4
Press
Select
.
5
Press the
Down
button until the
Disabled
setting is selected.
6
Press
Select
.
7
through
to disable any other unused drive bays.
8
Press
Main
to return to the main screen.
9
Turn the library off and then back on again.
The library is now ready for operation.
Caution:
Set the drive SCSI ID to
Disabled
only if there is no drive
installed in the drive bay.
Note:
This setting takes affect after you reboot the library.
Note:
It is recommended that you check the library configuration
settings and change them as necessary before configuring your
backup software, especially the
Import/Export
option setting.