Tandberg Data M-Series Installation Guide
Document T6423046-02 A01
February 2004
Installing a Rack Mount Library
17
These inserts will be screwed into the holes in the front and rear flanges
of the rack mount shelves.
2
Once you have selected the inserts for your rack, set the others aside. You
will not need them for this installation.
3
Screw three inserts into the front flange of each rack mount shelf in
positions 2, 6, and 10 (counting from the bottom up, with 1 being the
lowest hole) (see
).
Figure 13 Installing Inserts
at the Front of the Shelves
4
Screw three inserts into the rear flange of each rack mount shelf in the
positions shown in
. If the shelves are oriented so the group of
six holes is at the bottom and the group of four holes is at the top, the
inserts go into holes 2, 6, and 9 (counting from the bottom up, with 1
being the lowest hole).
Note:
Some of the inserts have either no head or a head that has a
smaller diameter than the thread; these need to be left
protruding by about 1/8 in. (3 mm). The inserts with heads
should be tightened fully.
Note:
Some of the inserts have either no head or a head that has a
smaller diameter than the thread; these need to be left
protruding by about 1/8 in. (3 mm). The inserts with heads
should be tightened fully.
10
6
2
10
6
2