Tandberg Data M-Series Installation Guide
Document T6423046-02 A01
February 2004
16
Installing a Rack Mount Library
Figure 11 Identifying the
Shelf Extender Slots
Figure 12 Attaching the
Shelves to the Extenders
Installing the Shelves in a Half U Position
0
To install the rack mount shelves in a half U position:
1
From the five sizes of inserts provided in the rack mount kit, select the
insert type that best fits into the holes in the rack rails. The heads of the
inserts (not the threads) should fit into the holes in the rack rails smoothly
and with very little play.
The insert part numbers are:
• 213468 (for rails with 9 mm square holes)
• 213469 (for rails with 7 mm diameter unthreaded holes)
• 213471 (for rails with M6 threaded holes)
• 213473 (for rails with 10-32 UNF, 12-24 UNC, or M5 threaded holes)
• 213474 (for rails with 1/4 inch diameter unthreaded holes)
Note:
The top and bottom libraries in a 3-high M2500 stack are mounted
in a half U position.
A
A
B
B
C
C
D
D
A
A
B
B
C
C
D
D
Shelf
Extender