Main Menu
GOLDEN EAGLE
Submenu Probe Setup
Select the
PROBE SETUP MENU
from the
AUTO COLOR MENU
with the
UP
and
DOWN
keys and open the
menu step with the
PLUS
(
V+
) key.
The
PROBE SETUP MENU
shows following operational steps:
Auto Color
Probe Setup
Help
Probe Setup
2
TFM6
selects probe type TFM6 (THOMA)
Calibrate
PM5639
selects probe type PM5664 (DK-PTV)
Brightness
Pluto
selects probe type Pluto
Measure
Mode
Fine
toggles between FINE and COARSE mode
Status
Idle
Color K
6504
selects the reference color temperature
x
0
Gamma 2.2
enables the recommended TV gamma function
y
0
Dicom
enables the medical gamma function
Y cd/m
2
0
Max Y
80
set the luminance value for the alignment
Whitepoint x
307
Default
8
reset to default setup
Whitepoint y
321
User Gamma
Note:
To prepare any alignment use the Probe Setup menu, Select the correct type of probe,
the style of measuring and the values for color temperature, gamma and luminance!
Note:
The alignment mode FINE is more precise and needs much more time to measure then
the mode COARSE.
Close and save this menu step by pushing the
MENU
key once.