![tams elektronik B-6 Скачать руководство пользователя страница 33](http://html2.mh-extra.com/html/tams-elektronik/b-6/b-6_manual_3469531033.webp)
t
a
ms elektronik
Booster B-6
6.2. Activating the Watchdog
When delivered, the Booster B-6 is not assigned a turnout address for switching the watchdog
on and off. To be able to use the function, you must therefore first assign a turnout address to
the B-6.
→ Section 5.2 "Main track programming", input value for CV 7: 76
To activate and deactivate the watchdog, send a turnout setting command to the turnout
address you have assigned to the booster for this function.
Turnout "straight ahead": Watchdog active
Turnout "branch": Watchdog inactive
After switching on the booster, the watchdog function is initially inactive. This gives you the
option of controlling the layout without PC control without first deactivating the watchdog
function. To activate the function, you must therefore first send the control command
"Turnout straight ahead" to the assigned turnout address after switching on.
6.3. Switching the track voltage on and off
6.3.1. 6.3.1 Manual switching on and off of the track voltage
STOP-GO button
By briefly pressing the button, you switch the track voltage on or off at the output of the
booster. The display and the RGB LEDs indicate the operating status of the B-6 and the digital
control unit (→ section 6.1.2 "Display and RGB LEDs").
Turnout setting commands
Provided that the function "Switching on and off with a DCC turnout command" is activated
(→ section 5.2 "Main track programming", input value for CV 7: 73), you can switch the track
voltage on and off at the output of the booster with a DCC turnout setting command. Send the
command to the turnout address you have assigned to the booster for this function.
Turnout "straight ahead": track voltage on
Turnout "branch": track voltage off
6.3.2. Autostart function
→ section 5.2 "Main track programming", input values for CV 7:
80 = Autostart active | 81 = Autostart inactive
When the autostart function is active, the track voltage at the booster output is automatically
switched on as soon as the track signal is present (the control unit is set to "GO") and the
track voltage at the booster output has not been switched off with the STOP-GO button
before. If, on the other hand, the track voltage at the booster output was switched off with a
switch setting command, it is automatically switched on again when a track signal is present.
The autostart function does not take effect if the booster has been switched off due to
overheating or by triggering the watchdog.
If the autostart function is set to inactive, the automatic switching on of the track voltage at
the output of the B-6 is prevented (e.g. after manually setting the control unit to "GO" or after
eliminating a short circuit on the layout). In this case, the RGB LEDs light up yellow (→ section
Operation | 33
Содержание B-6
Страница 1: ...B 6 Booster for digital model railway layouts Item no 40 19607 Manual Front Back tams elektronik n n n...
Страница 45: ...tams elektronik Booster B 6...
Страница 46: ...Booster B 6 tams elektronik...
Страница 47: ...tams elektronik Booster B 6...