Booster B-6
Function
Input
value for
CV 7
Setting / Comment
Display
Start programming
mode
62
To change settings, you must enter a
value for CV 7 again within 30 seconds.
Otherwise, the programming mode is
automatically terminated.
Reset
7
To reset all settings to the default values
(= values at delivery).
→ The RGB LEDs light up purple.
rE
Track voltage
Default value: 18 V
→ Section 5.3
"Recommendations for
the settings"
8
8 V
08
9
9 V
09
10 … 21
11 … 21 V
10 … 21
22
22 V
22
Restart time after
short circuit
Default value:
4 seconds
34
4 sec.
t4
35
5 sec.
t5
36 … 39
6 … 9 sec.
t6 … t9
40
10 sec.
t1
Maximum track
current
(Switch-off current in case of
short circuit)
Default value: 4 A
→ Section 5.3
"Recommendations for
the settings".
42
2 A
2A
43
3 A
3A
44 … 46
4 A … 6 A
4A … 6A
RailCom
Default value: active
51
RailCom active
r1
52
RailCom inactive
r0
Switching on and off
with DCC turnout
command
Default value:
–- / inactive
73
→ The RGB LEDs flash blue.
Switch to switch turnouts on your digital
control. Set the desired turnout address
and enter a turnout setting command for
this address ("straight ahead" for "GO" or
"branch" for "STOP"). The turnout
address and operating state are now set.
Settings / Configuration | 27