Chapter 3: Printer Menus and the Control Panel
3–57
Config Menu
⇒
Codes
Code 7F
This parameter allows you to dictate how the printer will react when it receives
a Hexadecimal code 7F. The default value depends on the emulation. (See
the Emulation Parameter, presented earlier in this chapter.)
Ignore:
The code is ignored.
Delete Char:
The previous character is deleted.
Delete Buffer:
The previous characters on the current print line are deleted.
Space:
A Space character is substituted.
Fill:
A Fill character is substituted.
Print 80 - 9F Hex
This parameter defines whether locations 80 through 9F Hex are to be treated
as control characters or printable characters. The function of the control
characters in this area depends on the emulation. The options are ON (print-
able characters) – the default, or OFF (control characters).
Ignore Char
This parameter allows you to select a character that will be ignored in the
incoming data stream. Ignore Char functions in all emulations and non-
downloadable print modes. It does not function in plot mode, font download,
or VFU download. Options are 0-255, referring to the decimal value of any 8-
bit character, or OFF. Default is OFF.
Sub Char From
This parameter allows you to select a character that will be replaced by the
character designated by the Sub Char To parameter. It functions in all emula-
tions and non-downloadable print modes. It does not function in plot mode,
font download, or VFU download. Default is OFF.
Sub Char To
This parameter allows you to select the character that will replace the character
designated by Sub Char From. It functions in all emulations and non-
downloadable print modes. It does not function in plot mode, font download,
or VFU download. Default is OFF.
Содержание 2900 -
Страница 1: ...Operator Manual 1 2900 Operator Manual Serial Parallel LAN ...
Страница 20: ...1 20 Operator Manual Blank Page ...
Страница 70: ...3 70 Operator Manual Blank Page ...
Страница 83: ...Appendix B Specifications B 83 Blank Page ...
Страница 84: ...4500 Daly Drive Suite 100 T 703 833 8700 Chantilly VA 20151 F 703 222 7629 www tallygenicom com 255069 001A ...