3–46
Operator Manual
Eject Delay
This parameter specifies the timeout interval in seconds (after which printing
will resume) when Quick Access is Enabled while the printer is Online. The
default is 30 seconds.
Impact
This parameter has three options: Auto, which is the default, Normal, and
High.
Paper Weight
The Paper Weight parameter defines the “paper moves” — how the paper
motion and printing work according to the thickness of the paper. If on
Auto
(the default), the selection will be either Light or Heavy depending on the
Print Gap setting.
On the Auto setting Paper Weight uses the print gap to sense what is needed.
However, in some cases you may want to set it manually. For example, very
dense (yet thin) paper may need to be assigned a heavy paper weight to ensure
good print quality.
Fast Slew
Slew refers to the high speed paper motion that occurs whenever the printer
moves paper more than one line. If your forms are not too thin or fragile such
that output stacking is a problem, you can decrease the printer’s slew speed by
setting this parameter to Disabled. The default setting is Enabled..
Double Strike
When this parameter is set to
Enabled
, the printer strikes each dot twice. Use
this to get better print quality when you are printing on an exceptionally thick
form. Default is
Disabled
.
Enabling Double Strike decreases the printer throughput by approximately
50%.
RibbonMonitor
This parameter enables the Ribbon Monitor feature. The options are
Enabled
and
Disabled
(default).
This feature helps the printer operator determine when to replace ribbons for
optimum and consistent print quality. It works by counting the estimated
number of characters printed as jobs are printed. Since ribbons are rated for an
estimated number of characters, when the character count threshold is reached
for the current ribbon the operator is notified via the panel that the ribbon
needs to be replaced.
Ribbon Monitor can be disabled at any time. However, the “characters printed count” is
reset to zero whenever Ribbon Monitor is enabled, so enabling the feature should only be
done with a fresh ribbon.
Operator Menu
⇒
Forms
Содержание 2900 -
Страница 1: ...Operator Manual 1 2900 Operator Manual Serial Parallel LAN ...
Страница 20: ...1 20 Operator Manual Blank Page ...
Страница 70: ...3 70 Operator Manual Blank Page ...
Страница 83: ...Appendix B Specifications B 83 Blank Page ...
Страница 84: ...4500 Daly Drive Suite 100 T 703 833 8700 Chantilly VA 20151 F 703 222 7629 www tallygenicom com 255069 001A ...