ENGLISH
2
Draining clear water
Model
P1=300
P1=600
Electrical data
P1 Rated absorbed power [W]
300 600
Mains voltage [V]
220-240 AC
220-240 AC
Mains frequency [Hz]
50 50
Current [A]
1.3 2.5
Capacitor [µF]
8 12.5
Capacitor [Vc]
450 450
Hydraulic data
Max. flow rate [l/min]
125
175
Max. head [m]
6.5
9
Max. head [bar]
0.65
0.9
Max. immersion depth [m]
7
7
Min. AUT starting height [mm]
115
115
Stopping height [mm]
45
45
AUT residual water height [mm]
2-3 2-3
Range of use
Length of power cable [m]
10
10
Type of cable
H05 RNF
H05 RNF
Grade of motor protection
IP X8
IP X8
Insulation class
F F
Liquid temperature range [°C]
according to EN 60335-2-41 for domestic use
0 °C / +35 °C
0 °C / +35 °C
Max. particle dimension [mm]
Ø 5
Ø 5
Max. ambient temperature [°C]
+40 °C
+40 °C
Weight
DNM GAS
1'' 1/4 M
1'' 1/4 M
Net/Gross weight approx. [kg]
4.8 / 5.5
5.3 / 6
Table 3
The pump which does not stand on a base cannot support the weight of the pipes, which must be
supported in some other way.
4. MANAGEMENT
4.1 Storage
All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.
4.2
Transport
Avoid subjecting the products to needless impacts and collisions.
4.3 Weight
and
dimensions
The adhesive plate on the packaging indicates the total weight of the pump and its dimensions.
5. WARNINGS
The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use
the handle provided.
The pump must never be allowed to run when dry.
The sealing device contains lubricant which is non-toxic but which may alter the characteristics of the water, in the
case of pure water, if the pump were to have any leaks.
6. INSTALLATION
Screw on the elbow with hosetail fitting provided in the packaging. Use a pipe tightening clamp to secure the pipe to the
fitting.
If the bottom of the trap where the pump is to be placed is particularly dirty, a raised support should be provided so as
to avoid blocking of the suction grid (Fig.1)
Totally immerse the pump in the water.
Ensure that the minimum dimensions of the trap in which it is housed are as follows:
Min. base dimensions (mm) 200x200 / Min. height (mm) 400
The dimensions of the trap must always be in relation to the quantity of water arriving and to the flow of the pump, so
as not to subject the motor to excessive starts/hour; it is strongly recommended not to exceed 20 starts/hour.
The pump must be installed in vertical position!
Содержание P1 300
Страница 28: ...26 20 7 3 8 1 220 240V 2 ON OFF 3 2 4 3 2 2 3 mm 5 1 9 0 C 10...
Страница 29: ...27 10 1 2 b c 10 2 3 b c d d 10 3 4 11 1 A B C A B C 2 A B C D E A B C D 1 3 A A 4 A B C A B C 5 A A B C o D...
Страница 30: ...28 12 24...
Страница 41: ...39 20 7 3 8 1 220 240V 2 ON OFF A 1 2 A M 2 3 2 M 2 3 mm 3 1 3 O 9 0 C 10...
Страница 42: ...40 10 1 2 b c 10 2 3 b c d d 10 3 4 11 1 A B C A B C 2 A B C D E A B C D 1 3 A A 4 A B C A B C...
Страница 43: ...41 5 A A B C D 12 To 24...
Страница 95: ...93 mm 200x200 mm 400 20 7 3 8 1 220 240 2 A 3 2 A M 4 3 2 M A 2 3 5 1 O 9 0 C 10...
Страница 96: ...94 10 1 2 b c 10 2 3 b c d d 10 3 4 11 1 A B C A B C 2 A B C D E A B C D 1 3 A A 4 A B C A B C 5 A A B C D...
Страница 97: ...95 12 24...
Страница 125: ...123 20 7 3 8 1 220 240 2 ON OFF A 3 2 A M 4 3 2 M 2 3 5 1 3 O 9 0 C 10...
Страница 126: ...124 10 1 2 b c 10 2 3 b c d d 10 3 4 11 1 A B C A B C 2 A B C D E A B C D 1 3 A A 4 A B C A B C...
Страница 127: ...125 5 A A B C D 12 24...
Страница 128: ...07 17 cod 60175189...