Programming the Command Unit
1.
There are two (2) methods to program the Command Unit:
•
Via the keypad on a Sub-Command Unit;
•
Remotely by calling the phone number of the connected PSTN/POTS telephone line.
In either case, the Command Unit will answer and output one (1) beep.
2.
When entering programming codes, the controller board will provide the following feedback:
One (1) Beep
Programming code successfully accepted
Two (2) Beeps
Error code
—please re-enter the programming code
If you hear two (2) beeps or silence, re-enter the programming code again. If you continue to
hear two (2) beeps or silence a second time, hang up and try again.
3. Remote Mode:
1. Pick up a Sub-Command Unit handset (or remotely call into the connected PSTN/POTS
telephone line) and listen for one (1) beep.
2. Enter the Guard Access Code to enter programming mode:
*31**
3. Program the controller board for Remote Mode:
*62*
4. Program the controller board for the type of PSTN/POTS telephone line:
*39*1*
for a CO line from the telephone company (allows 9 transfers)
*39*2*
for a PBX extension (disables 9 transfers)
5.
Recording the “On Hold” Voice Message for Calls in Queue or on Hold:
a. Record the location message for the AOR-CSE Station in question:
*58*
Wait for the tone to begin speaking/recording. The recorded message has a maximum
length of
50 seconds
.
b. Press the
#
key to stop recording or it will end after 50 seconds. The recorded
message will automatically play back.
c. To review the recorded message again, press:
*59*
d. To delete the recorded message, press:
*57*
6. To exit programming and disconnect, hang up the call or press:
#
7. Move onto
Programming the AOR-CSE Stations
(p.14).
4. Local Mode:
1. Pick up a Sub-Command Unit handset and listen for one (1) beep.
2. Enter the Guard Access Code to enter programming mode:
*31**
3. Program the controller board for Local Mode:
*37 *
4. Recording
the “On Hold” Voice Message for Calls in Queue or on Hold:
a. To begin recording, enter:
*58*