17. Connecting Primary Power:
Once the appropriate low voltage field cabling terminations have been completed, connect the
primary power (120/240 VAC, 50-60Hz) to the internal power supply located in the lower-left of
the Command Unit internal compartment.
The
L
(Line) and
N
(Neutral) terminals are located on the lower-left corner of the internal power
supply (see photo below). The AC ground should be connected to the bottom grounding terminal
on the internal power supply.
WARNING:
Once the backup batteries are connected, power will be supplied to the
Command Unit. Verify all connections and take precautions from unintended
electrical shock at this time.