Area of Refuge Command Unit
Installation Instructions
Model AOR-24/AOR-32
Page
8
of
13
Rev. 10/15/2015
Copyright 2014 Talk-A-Phone Co.
• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • info@talkaphone.com • www.talkaphone.com.
All prices and specifications are subject to change without notice.
Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talk-A-Phone Co. All rights reserved.
1.
Call the consolidator or pick up the built in handset and select the press the
phone line corresponding to the bank of phones/consolidator to be programmed
(listen for 3 beeps)
2.
Enter Guard Access Code: *31**
3.
Program the consolidator for Day/Night Mode: *63*
4.
Program the consolidator to call either:
Local first, then Remote: *35*
Remote first, then local: *36*
5.
If a PBX line is being connected to the Telco
“IN” port enter the PBX code:
*39*2*
6.
Move on to Programming the Talkaphone Area of Refuge Emergency Phones
Programming the Emergency/Information Phones
Once each Consolidator has been programmed, each Talkaphone Area of Refuge
Emergency Phone must be programmed individually. A call can be routed to the
desired phone port by entering the following code:
*4X*
Routes to Emergency phone in port jack number X (X=1-8)
For details on programming the Talkaphone Area of Refuge Emergency phones,
refer to the Installation & Operation Manual for Emergency/Information phones.
(Note: if the Consolidator is in Remote Mode or Day/Night Mode and your remote
phone line is a PBX extension, be sure to program the emergency phones for Mode
2. See Emergency Phone Manual, pages 11 and 15 for more information on
Modes).
Code Summary
Command
Function
*31* …[up to 8
digits]*
Guard Access Code entry for phone programming
(Default Code is *31**)
*30* …[up to 8
digits]*
Master Access Code entry to change Guard Access
Code or Master Access Code
(Default Code is
*30*12345678*)
*30*14725836*
Resets Consolidator programming to factory defaults
*32* …[up to 8
digits]*
Programs and stores a new Master Access Code
*33* …[up to 8
digits]*
Programs and stores a new Guard Access Code
*34* …[up to 2
digits]*
Sets number of rings before consolidator picks up when
it is dialed
*62*
Remote Mode (default)
Содержание AOR-16