Содержание Ultraf Pro

Страница 1: ...Installation and Operation Guide Table of Contents 1 Safety 2 Introduction 3 Package Contents 4 Installation 5 Setup and Configuration 6 Operation 7 Maintenance 8 Troubleshooting 9 Specifications...

Страница 2: ...cations to the meter might impair the function and or safety and reduce the lifespan of the meter Lifting Components Use caution when lifting components during installation Only authorized personnel u...

Страница 3: ...reads the water flow and the readings are monitored on the Ultraf local control panel see Local Monitoring on page 25 or via a dedicated mobile device application see Setup and Configuration on page 1...

Страница 4: ...alog current is related to the flow rate The reading is configured via Raphael mobile device application see Analog Output Control on page 21 Ultraf for Pressure Management Ultraf reads the water flow...

Страница 5: ...roller unit are Local display 2 a digital panel protected by a cover 1 displays the Ultraf readings and statuses see Local Monitoring on page 25 Main Battery enclosure 3 contains the lithium battery t...

Страница 6: ...label located on the control panel cover indicates the product serial number 1 The serial number is the Ultraf default identification on the mobile device application This serial number is used to ide...

Страница 7: ...o metric units 1 Ultraf Installation and Operation Manual When ordered fully trimmed with hydraulic application Ultraf is delivered in a cardboard transport box with styrofoam padding and includes 1 U...

Страница 8: ...scribes the tasks associated with Ultraf mechanical installation Dimensions When preparing the pipe line for Ultraf installation consider the following measurements according to the Ultraf model order...

Страница 9: ...hand Final tightening is performed according to pipe size specifications Recommended Installation Optional Installation Incorrect Installation Installing Ultraf in the optional installation location i...

Страница 10: ...rmance A minimum of two pipe diameters after elbows 90 A minimum of two pipe diameters after an isolating valve A minimum of ten pipe diameters after pumps A minimum of two pipe diameters after strain...

Страница 11: ...tput Ultraf Basic Pulse Output Analog Output Solenoid Valve Output Ultraf Basic Ultraf Basic is used for flow metering only and delivered without an output signal In this configuration Ultraf is deliv...

Страница 12: ...red to Irrigation controller Flow controller Water flow logging Output specifications Pulse type Open Collector N CH Mosfet Maximum Current 100 mA Maximum voltage 18VDC Pulse width 1 second 0 1 Wiring...

Страница 13: ...onnect the Ultraf red wire to the terminal on the 12 36 VDC power supply 2 Connect the terminal on the 12 36 VDC power supply to the Analog Input terminal on the reading device 3 Connect the Ultraf bl...

Страница 14: ...sed for pressure management applications In this configuration Ultraf is delivered with an additional pulse output see Pulse Output on page 12 Output specifications Solenoid type 12 18 VDC latch C 4 7...

Страница 15: ...nning the Ultraf application and includes Mobile Application Installation Ultraf Configuration Mobile Application Installation To install Raphael Ultraf on a mobile device Search for Raphael Ultraf 1...

Страница 16: ...af Configuration This section describes the Ultraf configuration process using Ultraf mobile application and includes Connecting to Ultraf on page 16 Ultraf Basic Control on page 19 Pulse Output Contr...

Страница 17: ...lly searches for Ultraf devices using Bluetooth After the application detects a device a check mark icon appears on the screen NOTE The mobile device must be within Bluetooth proximity to the valve an...

Страница 18: ...ct Serial Number and Data on page 6 The default name can be changed to a descriptive name 3 in the Settings screen To connect tap the relevant Ultraf device icon 4 The following sections describe the...

Страница 19: ...lume units as selected in the Settings Screen Current Flow 3 displays the current water flow measured in flow units as selected in the Settings Screen Cards 4 displays the extension card currently use...

Страница 20: ...low 3 displays the current water flow measured in flow units as selected in the Settings Screen Pulse Resolution 4 displays the pulse volume selected in the Settings Screen Cards 5 displays the extens...

Страница 21: ...low units as selected in the Settings Screen Min Flow Res 4 the flow rate associated with the lowest 4 ma analog output current Max Flow Res 4 the flow rate associated with the highest 20 ma analog ou...

Страница 22: ...n Current Flow 3 displays the current water flow measured in flow units as selected in the Settings Screen High Pressure Time 4 displays the daily schedule when Ultraf switches to high outlet pressure...

Страница 23: ...gh pressure changeover Tap the check mark icon 4 to save the settings The Monitoring Screen appears Flow Value Mode In this mode Ultraf maintains high pressure when the water flow exceeds the flow set...

Страница 24: ...ance Check for leaks tighten bolts and fittings if necessary As Ultraf fills up with water the Water Flow icon 1 on the local display transforms to a single black triangle Once Ultraf is full of water...

Страница 25: ...flow 3 Clock indicates that Ultraf internal clock is synced with the local time zone upon initial application communication Calendar indicates that irrigation controller is configured When blinking i...

Страница 26: ...hen bluetooth is connected 9 Alarm displayed when air is detected in the water the main battery is low Bluetooth malfunction or when water is flowing backwards See 8 Troubleshooting on page 29 10 Flow...

Страница 27: ...the Main Battery Status icon 1 on the local display drops to a single line there are about 6 months of operation left before the battery discharges completely An authorized Raphael dealer must be cont...

Страница 28: ...th compartments To replace the battery 1 Unscrew the screws 2 of the battery compartment using a 4mm Allen wrench 2 Remove the cover of the battery compartment 3 3 Remove the old battery 4 Place the n...

Страница 29: ...ctive Actions Verify that water is flowing through Ultraf in the proper direction and all measuring units are set to need Check the 9VDC battery and replace if needed see Secondary Battery Replacement...

Страница 30: ...traf output is not activated Corrective Actions Verify that water is flowing through Ultraf in the proper direction and all measuring units are set to need Initiate solenoid valve activation by changi...

Страница 31: ...Low Battery Problem Description The Main Battery Status icon 1 on the local display drops to a single line and starts flashing In this case there is about one month of operation left before the batter...

Страница 32: ...uring unit preference selection and controller settings Separate volume pulse output and external card for 4 20mA continues volume output 16 bar pressure rating Available in all flange standards from...

Страница 33: ...8 Starting flow 0 2 0 3 0 5 0 5 Q1 0 5 0 8 2 0 3 2 Q2 0 8 1 3 3 2 5 1 Q2 1 22 3 35 4 88 6 141 8 Q2 2 44 7 70 9 177 2 283 6 Q3 63 0 100 250 0 400 Q4 78 8 125 312 5 500 R Q3 Q1 125 125 125 125 Accordin...

Страница 34: ...y third party reproduction duplication publication or use of the Information in whole or in part for any purpose other than the conduct of business with TALIS or for the purpose stated herein is expre...