31
Detailed information about the
pH/EC Interface
can be found in the manual “
FERTMASTER
pH/EC USER GUIDE 2007
”.
5.6
THD Interface
The
THD interface
is meant to measure the ambient
Temperature
and
Humidity
, calculate
the actual
Dew point
and report the three values back to the controller. The values can then
be used for frost protection or conditioning of cooling programs. During the configuration
process when defining the hardware in use, the
THD interface
will be defined as an analog
interface of the type
THD
. Like any other interface it has an address switch that has to be set
according to what has been defined at the configuration process.
The scale range is automatically adjusted and need not be touched, however for obtaining the
values in American units JP14 on the THD board must be set in right position.
External interface
connection card
THD interface card
Temperature and
Humidity sensor
Address switch
JP14 set to USA
units
JP14 set to
European units