Takex PoCL FC1600FPL Скачать руководство пользователя страница 7

K11823;7/34 

- 7 - 

LED operation 
indicator 

(4-2)  Input of Vinit signal (asynchronous trigger signal)   

  How to input Vinit signal 

If the camera is used in the asynchronous shutter mode, the Vinit signal (asynchronous trigger signal) must be input 
from the user side unit.   
The Vinit signal is input from Pin (4) of the “I/O” connector (6 pin connector) on the rear of the camera, or is input as 
the CC1 signal from the “Camera Link” connector.   
 

(Note) 

OR  operation  (negative  OR)  is  implemented  inside  the camera  between  Vinit1  input  signal  of  “I/O”  and  Vinit2 input signal 
CC1 of “Camera Link” (see the figure below).   

(Note) 

If  either  one  of  those  are  fixed  to  the  L  level  (active  state), 
the Vinit signal (logical sum) is also fixed to the L level and 
the  trailing  edge  signal  cannot  be  obtained.  This  would 
result  in  failure  in  starting  up  the  asynchronous  shutter 
operation.  Make  sure  to  fix  the  input  signal  on  the  unused 
side  to  the  H  level,  to  keep  it  at  high  impedance  level  or 
open state (no connection).   

 

  LED Vinit signal monitor indicator 

When this camera is set in the asynchronous shutter mode,   
the LED indicator on the rear panel of the camera lights up in red   
for one shot in response to the input of the external trigger signal   
(Vinit signal). This allows the user to confirm the state of signal input.

 

 

The red LED lights up for a certain period of time (about 100 ms) on   
each trailing edge of the trigger input pulse. If a next trigger signal is   
input within this period, the lighting time of the LED will be retriggered   
and extended. Since the lighting of the LED responses only to the trailing   
edge of the trigger input, it lights up only once for 100 ms even if the trigger   
input pulse duration is longer than the one shot time of period.   
                                                                                                                                                                                                                                         

  Setting of various asynchronous shutter modes 

Set the parameters and others in accordance with the following table: 

Table 4-1 Setting of various asynchronous shutter modes 

Asynchronous shutter mode 

Double pulse 

(2 TRIG) 

PWC 

Shutter switch 

Remark 

Preset shutter (PWC=DISABLED) 

DISABLED 

DISABLED 

1 to 9 

 

Preset shutter (PWC=ENABLED) 

ENABLED 

1 to 8 

 

Pulse width control 

Shutter switch = 1 to 8: same as preset shutter 

 
(Note)  When shutter switch is 0, “Continuous image output (without shutter)” is applied for the all.   
(Note)  For setting methods for the respective parameters of “PWC” and others 

 See “(6-3) How to set operation mode”. 

 

  Recommended timing of asynchronous shutter

 

trigger signal (Vinit signal) for preset shutter/pulse width control   

For the case of preset shutter mode, the negative logic pulse is 
applied  within  the  width  range  from  1H  (1  horizontal 
synchronous interval) to 40 H as described below. 
For this case, the exposure operation starts in synchronization 
with the trailing edge timing of the applied pulse. 
For  the  case  of  the  pulse  width  control  exposure  mode, 
numeric  value  of  the  L  level  interval  of  the  input  Vinit  pulse 
(shown  as  Tvinit  in  the  figure)  is  retrieved  in  synchronization 
with  the  HD  trailing  edge  inside  the  camera,  and  the  integer 
multiple number of H (1 horizontal synchronous interval) that is 
closest  to  the  retrieved  Vinit  pulse  duration  is  transmitted  as 
nH  to  the  inside  of  the  camera.  Then  the  shutter  speed  is 
determined in response to the time nH. 
 

 

Vinit

 

Tvinit

 

 

[For the case of preset shutter mode] 

1H 

 Tvinit 

 40H 

(The shutter speed is independent of the Vinit width.) 
1H=31.23

µ

sec 

 

  [For the case of pulse width control mode] 

(Where PWC=ENABLED, shutter switch = 9) 
nH 

 Tvinit <(n+1)H (n is 1 or larger integer.) 

(This is the pulse width where shutter exposure time =nH) 
 

Fig. 4-3 Recommended Vinit signal timing waveform

 

(Note)  In  the  pulse  width  control,  the  shutter  exposure  time  is  almost  equal  to  the  integral  multiple  number  of  the  horizontal 

synchronous time  (H)  that is  closest to the  Vinit  pulse  duration.  More  specifically,  however,  the  shutter  exposure  time  is 
indefinite for the time period corresponding to 1H width in the case of normal external trigger input (or the case where the 
Vinit  signal  is  not  in  synchronization  with  the  horizontal  synchronous  timing  of  the  camera) 

  Refer  to  the  timing  chart 

described in another section for the details.   

(Note)  When the shutter exposure time is too long in the pulse width control mode, the S/N ratio of the image will be degraded due 

to the reduction of dynamic range of CCD, accumulation of thermal noise components of CCD imaging device in proportion 
to  the  shutter  speed  and  other  factors.  Therefore,  if  a  long  exposure  time  is  employed,  it  is  recommended  to  conduct 
experiments using realistic exposure times in actual conditions to check for the appropriateness.   

 

 
 
 
 
 

 

"CC1” (Vinit 2)

 

H

 

 

Internal circuit 

 

"I/O” - 4 (Vinit 1)

 

Fig. 4-2    Internal connection of Vinit signals 

FC - PL camera 

I/O

EXP.

MODE

C a me r a L i n k

Red LED lights up in response to   
trigger signal input (Vinit). 

Содержание PoCL FC1600FPL

Страница 1: ...ly and manage the camera properly Keep this manual at hand and reread it whenever you are uncertain about the operation Table of Contents 1 Features 3 2 Outline 3 3 Description of each component 4 4 H...

Страница 2: ...Error correction H Reset function added 2011 05 19 K11519 Adapted since Firmware Ver 1 13 7th version Error correction 2011 08 23 K11823 Description of special remarks used in this manual Note Partic...

Страница 3: ...this contributes to the power saving for LED lighting and others as well as the reduction of smear The ID information set by the user for each camera can be saved and read out whenever necessary via...

Страница 4: ...are shown in the following table Pin arrangement of Camera Link connector SDR 26 Connector 26 13 14 1 Mini Camera Link External view of Camera Link connector Viewed from the outside of the camera Not...

Страница 5: ...PORTC7 D07 O PORTB0 PORTB4 D08 O PORTB1 PORTB5 D09 O Uppermost data PORTB2 3 6 7 O Fixed to L level CC1 Vinit2 I Asynchronous shutter trigger CC2 reserved I Reserved for future products CC3 reserved...

Страница 6: ...ing the UP DOWN switch lever to the upper position or lower position 3 Return the UP DOWN switch lever to the neutral position after having heard a buzzer sounding pip pip 4 Set the mode switch to the...

Страница 7: ...ive parameters of PWC and others See 6 3 How to set operation mode Recommended timing of asynchronous shutter trigger signal Vinit signal for preset shutter pulse width control For the case of preset...

Страница 8: ...the lighting in any time other than this exposure time period would be wasted Since this equipment is capable of outputting strobe signal STRB even in the continuous shutter mode this output is used a...

Страница 9: ...l temperature of the camera Turn on the MENU display and confirm it by the OSD over the image Temperature to be displayed in Celsius Confirm it by temperature data to be returned in response to the RS...

Страница 10: ...ordance with 1 3 The signed number is obtained from 1 for the sign and 2 for the absolute value In the case of the Example 2 as above its sign is because the MSB is 1 in accordance with 1 The absolute...

Страница 11: ...Partial scan The read out for each frame is conducted by the partial readout scanning The vertical width of the longitudinal picture area corresponds to 398 lines of the central portion of the image...

Страница 12: ...ng The level setting is mostly divided into the following two groups Gain setting This is to set the gain amplification ratio of the preamplifier between the CCD imaging device inside the camera to A...

Страница 13: ...white look inverted at the saturating area The outline of the saturating area is blurred The saturating area slightly shifts upward or downward The brightness value of the saturating area does not re...

Страница 14: ...r this camera it must be set to be Pulse width control PWC ENABLED for implementing Pulse width control asynchronous shutter operation When it is set to be Pulse width control PWC DISABLED default the...

Страница 15: ...om A to F Write Read When the setting of Enabled disabled for pulse width control is not set to be ENABLED the pulse width control is not effective even if the shutter switch is set to the position 9...

Страница 16: ...y when the camera is turned on and that determines the operation of the camera as the current setting When the setting of a mode is changed the older one is overwritten and the new setting is temporar...

Страница 17: ...ous shutter mode the repetitive trigger cyclic trigger that is generated inside the camera is automatically input Make sure to set the menu display OFF when the camera is used in the normal state onli...

Страница 18: ...nged on the menu These are automatically updated when a corresponding change is made using the switches MS The current position of the mode switch is displayed SS The current position of the shutter s...

Страница 19: ...the camera is turned on the data stored in the internal EEPROM nonvolatile storage are read out and copied into these areas The current operation mode of the camera is determined by the data in FR and...

Страница 20: ...panel of the camera The operation modes that cannot be changed by the RS 232C commands can be changed by altering the bits of CR and FR Example 1 When a change is made from the continuous shutter mode...

Страница 21: ...gger is internally generated in the cyclic trigger state when the menu is displayed therefore it is not necessary to temporarily switch to the continuous shutter operation as shown above when the menu...

Страница 22: ...out are automatically saved in the program pages from A to F Carefully note that the earlier setting data that were saved by the user are all overwritten and lost Fig 6 5 Setting contents immediately...

Страница 23: ...ning to power on state is received even during the periods when the camera is in the operation modes of Group 2 to D Description of commands 1 Command e Function Initialization of page memory Transmis...

Страница 24: ...tter mode and shutter exposure time Transmission from host STX S A or M H or L N or P exposure time ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The tra...

Страница 25: ...age A to H ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The factory default is stored in the Page H which will be used when resetting to the default set...

Страница 26: ...synchronous trigger signal The internally generated trigger signal is of negative logic at 100ms 5 The minimum repetition pitch is approx 300ms Only when the trigger signal is input by this command th...

Страница 27: ...on or STX NAK ETX transaction rejection The data 0 up to 15 characters of the ID code character string is read out When an ID code is not set the number of the characters to be returned is 0 20 Comman...

Страница 28: ...OFFSET setting value STX WOF 64 00 ETX 27 Command RPS Function Command for reading preset Read PRESET Transmission from host STX RPS ETX Return by camera STX ACK RPS PRESET No ETX When gain and offset...

Страница 29: ...erefore there is no compatibility with the conventional parallel type camera FC2000CL etc and so dedicated setting files are required Note When a channel link device is mounted directly to the capture...

Страница 30: ...image 3 2 2 3 23 3 24 7 17 7 18 71 9 Partia l sca n N orma l sca n Intenal signal End of exposure Digitaloutpu t CH1 2 Unless otherwise specified the time unit of the numbers in the vertical timing ch...

Страница 31: ...e becomes indefinite for the period of 1H shutter speed when a Vinit signal that is not in synchronization with the internal horizontal synchronous signal HD is input from the user side Some of the co...

Страница 32: ...lues and the actual equipment should be checked for the details Vertical timing Low speed long exposure preset shutter continuous normal scan Timing of long exposure mode Internal signal internal oper...

Страница 33: ...pment and remove the power cable and external connection cables When an abnormal or failure condition is detected immediately stop using this equipment cut off the power supply remove the external con...

Страница 34: ...ternal Dimensions External dimensions 21 42 46 9 2 60 26 30 7 4 31 M3 Depth Depth Depth 34 40 13 5 11 11 26 Depth Right and left sides MO DE EXP U D Camera Link I O Same as top side Depth Fig 11 1 FC1...