Takex PoCL FC1600FPL Скачать руководство пользователя страница 23

K11823;23/34 

- 23 - 

7.  Serial Communication Control 

 
FC1600FPL can be externally controlled by serial communication via Camera Link.   
 
(Note)  When the operation modes of the camera are changed by the communication functions, it takes some time to switch the 

modes.  Carefully  note  that  normal  image  may  not  be  obtained  from  the  signal  for  each  one  frame  before  and  after 
transmitting a command.   

(Note)  The  settings  and  timings  of  the  serial  communication  commands  are  the  same  as  those  of  the  products  that  have  the 

conventional RS-232C communication functions.   

 

  The setting of the serial communication is as follows: 

Baud rate 

: 9600bps or 19200bps (Specified by Setting Group 2, default: 9600bps) 

Data   

: 8bit/character 

Stop bit 

: 1stop bit 

Parity 

: none 

XON/XOFF  : no control 

 

  Serial communication commands 

The command packet starts with STX(02h), followed by command code(s) and command option parameter(s) and ends with 
ETX(03h). All those are of 8 bit ASCII codes.   
When  the  camera  receives  1  packet  (by  detecting  ETX:03h)  and  judges  it  is  a  normal  packet,  it  returns  a  transaction 
completion signal (ACK: 06h) or others corresponding to the commands received. When the camera judges it is an abnormal 
packet, it returns the abnormal signal (NAK: 15h).   

 

  Operation mode “Group 1/2” and reception of serial communication commands   

Serial communication commands are received only for the period when the camera is in the operation mode of “Group 1” (= 
“normal power-on state”). However, only the command “ARESET” (returning to power-on state) is received even during the 
periods when the camera is in the operation modes of Group 2 to D. 

 

  Description of commands 

 
(1) Command “e” 

Function: Initialization of page memory 
 
Transmission from host:  STX: “e”: ETX 
Return by camera: 

STX: ACK: ETX (transaction completion), or STX: NAK: ETX (transaction rejection) 

 
*  CPU initializes each of the page memories when the power is turned on next time. “Initialization” here means returning 

the parameter values stored in the internal EEPROM of the camera to the factory default values.   

 

(2) Command “R” 

Function: Command for reporting camera operation and setting status 
The contents of the report can be selected by adding the following option code after the command code “R”.   
G: Gain report 
V: Camera version report 
T: Shutter SW set report 
S: Shutter mode report 
 
1)  Gain report 

Transmission from host:  STX: “R”: “G”: ETX 
Return by camera: 

STX: ACK: “R”: MGC setting value: (AGC setting value): (VRT setting value): 
(VRB setting value): OFFSET setting value: ETX 

 
(!)  FC1600FPL does not use the values in parentheses. This camera returns the fixed values instead.   
 

2)  Camera version report 

Transmission from host:  STX: “R”: “V”: ETX 
Return by camera: 

STX: ACK: “R”: 
“Takenaka SYS.FC1600FPL V1.00”: ETX 

 
*  The underlined values show the control program version number of the camera and a file name. These values and 

the number of characters vary by program version. Use when confirming the communication mode of the camera 
and obtaining internal information of the camera.   
The maximum number of the characters to be inserted between ACK and ETX is 48. 

 

3)  Shutter SW report 

Transmission from host:  STX: “R”: “T”: “H”: ETX 
Return by camera: 

STX: ACK: “R”: “H”: 
SW0: SW1: SW2: SW3: SW4: SW5: SW6: SW7: SW8: SW9: ETX 

 

Содержание PoCL FC1600FPL

Страница 1: ...ly and manage the camera properly Keep this manual at hand and reread it whenever you are uncertain about the operation Table of Contents 1 Features 3 2 Outline 3 3 Description of each component 4 4 H...

Страница 2: ...Error correction H Reset function added 2011 05 19 K11519 Adapted since Firmware Ver 1 13 7th version Error correction 2011 08 23 K11823 Description of special remarks used in this manual Note Partic...

Страница 3: ...this contributes to the power saving for LED lighting and others as well as the reduction of smear The ID information set by the user for each camera can be saved and read out whenever necessary via...

Страница 4: ...are shown in the following table Pin arrangement of Camera Link connector SDR 26 Connector 26 13 14 1 Mini Camera Link External view of Camera Link connector Viewed from the outside of the camera Not...

Страница 5: ...PORTC7 D07 O PORTB0 PORTB4 D08 O PORTB1 PORTB5 D09 O Uppermost data PORTB2 3 6 7 O Fixed to L level CC1 Vinit2 I Asynchronous shutter trigger CC2 reserved I Reserved for future products CC3 reserved...

Страница 6: ...ing the UP DOWN switch lever to the upper position or lower position 3 Return the UP DOWN switch lever to the neutral position after having heard a buzzer sounding pip pip 4 Set the mode switch to the...

Страница 7: ...ive parameters of PWC and others See 6 3 How to set operation mode Recommended timing of asynchronous shutter trigger signal Vinit signal for preset shutter pulse width control For the case of preset...

Страница 8: ...the lighting in any time other than this exposure time period would be wasted Since this equipment is capable of outputting strobe signal STRB even in the continuous shutter mode this output is used a...

Страница 9: ...l temperature of the camera Turn on the MENU display and confirm it by the OSD over the image Temperature to be displayed in Celsius Confirm it by temperature data to be returned in response to the RS...

Страница 10: ...ordance with 1 3 The signed number is obtained from 1 for the sign and 2 for the absolute value In the case of the Example 2 as above its sign is because the MSB is 1 in accordance with 1 The absolute...

Страница 11: ...Partial scan The read out for each frame is conducted by the partial readout scanning The vertical width of the longitudinal picture area corresponds to 398 lines of the central portion of the image...

Страница 12: ...ng The level setting is mostly divided into the following two groups Gain setting This is to set the gain amplification ratio of the preamplifier between the CCD imaging device inside the camera to A...

Страница 13: ...white look inverted at the saturating area The outline of the saturating area is blurred The saturating area slightly shifts upward or downward The brightness value of the saturating area does not re...

Страница 14: ...r this camera it must be set to be Pulse width control PWC ENABLED for implementing Pulse width control asynchronous shutter operation When it is set to be Pulse width control PWC DISABLED default the...

Страница 15: ...om A to F Write Read When the setting of Enabled disabled for pulse width control is not set to be ENABLED the pulse width control is not effective even if the shutter switch is set to the position 9...

Страница 16: ...y when the camera is turned on and that determines the operation of the camera as the current setting When the setting of a mode is changed the older one is overwritten and the new setting is temporar...

Страница 17: ...ous shutter mode the repetitive trigger cyclic trigger that is generated inside the camera is automatically input Make sure to set the menu display OFF when the camera is used in the normal state onli...

Страница 18: ...nged on the menu These are automatically updated when a corresponding change is made using the switches MS The current position of the mode switch is displayed SS The current position of the shutter s...

Страница 19: ...the camera is turned on the data stored in the internal EEPROM nonvolatile storage are read out and copied into these areas The current operation mode of the camera is determined by the data in FR and...

Страница 20: ...panel of the camera The operation modes that cannot be changed by the RS 232C commands can be changed by altering the bits of CR and FR Example 1 When a change is made from the continuous shutter mode...

Страница 21: ...gger is internally generated in the cyclic trigger state when the menu is displayed therefore it is not necessary to temporarily switch to the continuous shutter operation as shown above when the menu...

Страница 22: ...out are automatically saved in the program pages from A to F Carefully note that the earlier setting data that were saved by the user are all overwritten and lost Fig 6 5 Setting contents immediately...

Страница 23: ...ning to power on state is received even during the periods when the camera is in the operation modes of Group 2 to D Description of commands 1 Command e Function Initialization of page memory Transmis...

Страница 24: ...tter mode and shutter exposure time Transmission from host STX S A or M H or L N or P exposure time ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The tra...

Страница 25: ...age A to H ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The factory default is stored in the Page H which will be used when resetting to the default set...

Страница 26: ...synchronous trigger signal The internally generated trigger signal is of negative logic at 100ms 5 The minimum repetition pitch is approx 300ms Only when the trigger signal is input by this command th...

Страница 27: ...on or STX NAK ETX transaction rejection The data 0 up to 15 characters of the ID code character string is read out When an ID code is not set the number of the characters to be returned is 0 20 Comman...

Страница 28: ...OFFSET setting value STX WOF 64 00 ETX 27 Command RPS Function Command for reading preset Read PRESET Transmission from host STX RPS ETX Return by camera STX ACK RPS PRESET No ETX When gain and offset...

Страница 29: ...erefore there is no compatibility with the conventional parallel type camera FC2000CL etc and so dedicated setting files are required Note When a channel link device is mounted directly to the capture...

Страница 30: ...image 3 2 2 3 23 3 24 7 17 7 18 71 9 Partia l sca n N orma l sca n Intenal signal End of exposure Digitaloutpu t CH1 2 Unless otherwise specified the time unit of the numbers in the vertical timing ch...

Страница 31: ...e becomes indefinite for the period of 1H shutter speed when a Vinit signal that is not in synchronization with the internal horizontal synchronous signal HD is input from the user side Some of the co...

Страница 32: ...lues and the actual equipment should be checked for the details Vertical timing Low speed long exposure preset shutter continuous normal scan Timing of long exposure mode Internal signal internal oper...

Страница 33: ...pment and remove the power cable and external connection cables When an abnormal or failure condition is detected immediately stop using this equipment cut off the power supply remove the external con...