![Takex PoCL FC1600FPL Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/takex/pocl-fc1600fpl/pocl-fc1600fpl_instruction-manual_3330311015.webp)
K11823;15/34
- 15 -
Table 6-2 Start-up condition for each setting Group
Start-up condition (at time of power-on)
The groups of Operation
Mode Setting
Operation state of camera at
start-up
Position of mode switch
UP/DOWN switch
Arbitrary position
from 0 to F
Neutral position
(no switch manipulation)
Group 1
By normal automatic loading (
→
Table 6-8)
Table 6-3 Set contents for Operation Mode Setting [Group 1]
Position of mode
switch
Item to be changed
UP/DOWN switch
UP position
DOWN position
0
Change of gain
Increase in gain
Decrease in gain
1
Menu display
(MENU)
<* C>
Group 2
Menu OFF
2
Preset select 1 or 2
Preset2 (±0dB)
Preset1 (-3dB)
3
Preset select 3 or 4
Preset4 (+1
2
dB)
Preset3 (+6dB)
4
(Not used)
5
Shutter – continuous/asynchronous (S.FORM )
Continuous (NORMAL)
Asynchronous (ASYNC)
6
Shutter – high speed/low speed
(S.TIME)
High speed (HIGH)
Low speed (LOW)
7
Change of shutter speed
(S.TIME)
Shorter
Longer
8
Digital offset
(OFFSET)
Increase in offset
Decrease in offset
9
Switch between normal scan/partial scan
(SCAN)
All pixels (NORMAL)
Partial (PARTIAL)
A to F
Program pages from A to F
Write
Read
(Note )The decibel value of Preset select is a relative value(reference value) based on Preset 2.
(Note) The shutter speed can be changed only when the shutter switch is currently set at any other positions than “0”.
When the shutter switch is positioned at “0”, the shutter speed cannot be changed even if the mode switch is set to
the position “7” and the UP/DOWN switch is manipulated. (The shutter is always OFF where shutter switch = “0”.)
Table 6-4 Set contents for Operation Mode Setting [Group 2]
Position of mode
switch
Item to be changed
UP/DOWN switch
UP position
DOWN position
1
Menu display
(MENU)
<* C>
Group C
Menu OFF
2 to3
(Not used)
-
-
4
Enabled/disabled for pulse width control (PWC) (!)
ENABLED
DISABLED
A to F
Program pages from A to F
Write
Read
(!) When the setting of “ Enabled/disabled for pulse width control” is not set to be “ENABLED”, the pulse width control is
not effective even if the shutter switch is set to the position “9” for the asynchronous shutter operation. In this case, the
preset shutter in asynchronous shutter mode is effective.
Table 6-5 Set contents for Operation Mode Setting [Group C]
Position of
mode switch
Item to be changed
UP/DOWN switch
UP position
DOWN position
1
Menu display
(MENU) <* C>
Group D
Menu OFF
2
Operation confirmation buzzer
(BZ) <* C>
ON
OFF
3
Serial communication baud rate
(BAUDP) <* C>
19200 bps
9600 bps
4
(Not used)
( - )
-
-
5
H-RESET in asynchronous shutter mode (H-RESET) <* C>
DISABLED
ENABLED
6
Polarity setting for Vinit2
(Vinit2) <* C>
Positive logic
(INVERTED)
Negative logic
(NORMAL)
7
Continuous shutter strobe signal
(STRB-C) <* C>
ON
OFF
(Note) Although this version of the firmware is designed to display the setting items of (CLOCK), any change made for
these items is disabled and not affect the internal operation. As a general rule, use with the default setting.
Table 6-6 Set contents for Operation Mode Setting [Group D]
Position of mode
switch
Item to be changed
UP/DOWN switch
UP position
DOWN position
1
Menu display
(MENU)
<* C>
Factory default
Menu OFF
2
Test pattern
(PATTERN)
<* C>
ON
OFF
3
Output bit
(BIT)
<* C>
10bit
8bit
4 to 7
(Not used)
( - )
-
-
Table 6-7 Set contents for Operation Mode Setting [Factory default]
Position of mode
switch
Item to be changed
UP/DOWN switch
UP position
DOWN position
0
Initialization
Initialization
Initialization
1
Menu display
(MENU)
<* C>
Group 1
Menu OFF
2
Read out default value
Read
Read
* Notes in common with all setting groups
(Note) The standard factory mode (default) is underlined.
(Note) The items marked with <* C> in the table (configuration items) are automatically stored in EEPROM whenever they
are changed.
(Note) The new settings of the other items than the configuration items are lost at the time of power-off unless they are
manually saved in the program pages after changing them.