* For open wiring, break the
knockout on the rear side
of the sensor unit, and
pull the wire through it.
&RQQHFWWKHZLUHVWRHDFK
WHUPLQDO
5HIHUWR´:,5,1*µ
6HWWKHGHWHFWLRQDUHDDQGIXQFWLRQVDFFRUGLQJ
WRWKHLQVWDOODWLRQVLWH5HIHUWR´'(7(&7,21
$5($µDQG´)81&7,21µ
$5($µ´$'-8670(172)'(7(&7,21
5HSODFHWKHFRYHUXQLW
DQGIL[LWE\WLJKWHQLQJ
WKHFRYHUORFNLQJ
VFUHZV
*When installing
outdoors, mount
the anti bird spike
above the cover
unit. Turn the anti
bird spike and
tighten it.
When mounting on the pole
[Use the pole attachment]
When mounting on the ceiling or under eaves
[Use the ceiling attachment]
When mounting the unit on a vertical pole, use the pole attachment
(sold separately). The unit can be mounted on poles of Dia 15
”
to 19
”
(
φ
38 to
φ
49mm) and Dia 15.7
”
to 55
”
(
φ
40 to
φ
140mm).
* Mount the sensor so that its mounting surface is placed vertically.
When mounting on the ceiling or under eaves,
use the ceiling attachment (sold separately).
* Mount the sensor so that its mounting surface
is placed vertically.
The installation height and adjustable detection distance depend on the
operation mode. Carefully check the operation mode and detection area
setting before installation and area setting.
:KHQWKHGHWHFWLRQDUHDDQGIXQFWLRQVVHWWLQJV
DUHFRPSOHWHGJRWRVHFWLRQ´23(5$7,21
&+(&.µ
* Installation height of the sensor should be
within 8.3
’
to 10
’
(2.5 to 3.0m) in the pet mode.
3ROH
attachment
%3)
3ROHGLDPHWHU
Dia 15
”
WR
”
ѮWRPP
3ROH
attachment
%3
3ROHGLDPHWHU
'LD
”
to 55
”
ѮWRPP
■
Mounting method
When using the pole
attachment BP-22F (sold
separately), break the
knockout on the rear side
of the sensor unit, and
attach it.
* Adjust the sensor installation height using
the center of the sensor housing as a guide.
8VHWKHXQLWZLWKWKHFRUUHFWRSHUDWLRQPRGHVHWWLQJ6HOHFWRSHUDWLRQPRGHWRXVHDQGSHUIRUPWKH
VHWWLQJFRUUHFWO\7KLVXQLWFDQEHRSHUDWHGIURP
①
to
④
PRGHVDVIROORZV
Normal operation modes
7KHUHDUHORZDQGKLJKSRVLWLRQPRGHVDFFRUGLQJWRWKHLQVWDOODWLRQKHLJKW
①
Low position mode
This can be used to reduce false detection caused by small animals. Set this mode when the
unit is mounted at a installation height of 6.6
’
to 9
’
(2.0 to 2.7m.)
②
High position mode
This can be used to reduce false detection caused by small animals. Set this mode when the
unit is installed at a mounting height of 9
’
to 11.5
’
(2.7 to 3.5m.)
* When the mounting height is 9
’
(2.7m), either low or high position mode can be set.
Specialized operation modes
7KLVLVDQRWKHURSHUDWLRQPRGHEHVLGHVQRUPDORQH7KHUHDUHSHWPRGHDQGKLJKGHQVLW\PRGH
③
Pet mode
Set this mode in order to reduce false detection caused by pets (dogs, cats) and small
animals. Install the unit at a installation height of 8.3
’
to 10
’
(2.5 to 3.0m.)
④
High density mode
Set this mode in order to significantly reduce non-detection of the human body in the
detection area. The unit can be installed at a mounting height of 6.6
’
to 20
’
(2.0 to 6.0m.)
Choose among the above four operation modes, and set with the mode selector. (Refer to “7
FUNCTION”)
Put the wires for power input and alarm
output through the wiring hole on the left,
and for tamper output and starting output
on the right. Be careful not to cross the
wires.
5
INSTALLATION
5
:LULQJ
3RZHU$ODUP
:LULQJ
7DPSHU([WHUQDO
&HQWHURI
the sensor
,QVWDOODWLRQKHLJKW
Pole
attachment
BP-22F
Ceiling
attachment
KP-32
Pole
attachment
BP-22F
Normal Operation
Specialized Operation
Low Position Mode High Position Mode
Pet Mode
High Density Mode
Mounting Height
6.6-9ft(2.0-2.7m) 9-11.5ft(2.7-3.5m) 8.3-10ft(2.5-3.0m) 6.6-20ft(2.0-6.0m)
Small Animal Tolerance
●
●
●
Pet Immune
●
Creep Zone Detection
●
(Selectable)
●
(Selectable)
●
Near Area Cancellation
●
(Selectable)
●
(Selectable)