background image

(1) Attach area masking sheet (accessory) to the lens holder 

of cover without cutting it out.

(2) Turn the sensor by 90º to the direction to be detected.
(3) Horizontal fine adjustment

Fine adjustment can be made within the range of ±3º, in 
case there are some obstacles on the wall.
(Detection zone shifts about 2’(0.6m) at 40’(12m) range.) 
Slide the lever to the left or right.

*

Make sure that the lever is set at 0º for horizontal 

detection.

(1) Cut the necessary area number on the area masking sheet.

See below area masking picture for your reference and cut 
out the same place on both horizontal and downward zones.

(2) Attach the area masking sheet to the lens holder located 

inside cover.

(3) Attach cover and check detection zone.

Detection distance adjustment
Detection distance can be adjusted within a range from 
10’(3m) to 40’(12m) by turning the angle of downward 
zone vertically.
Refer to the index and slide the adjustment lever up or 
down.
Slide it up and the detection distance becomes shorter, 
sliding it down, detection distance becomes longer.

Detection distance depends on how the sensor is
installed and how its sensitivity adjustment is set.

Area masking sheet

When shifting detection 
zone away from the wall, 
slide the lever towards 
the wall.

When shifting detection 
zone towards the wall, 
slide the lever away from
the wall.

• Zone 

cannot be masked by area masking sheet.

[Wall detection]

Index

Short distance

detection

Long distance

detection

Area masking sheet

Cut the necessary
area number

Cut the necessary
area number

Print side

Cut off

Lens holder

Adjustable
range

Adjustment lever

Horizontal zone

Horizontal zone

Downwar

d zone

Detection range

Downwar

d zone

Detection range

No detection

Содержание MS-12TE

Страница 1: ... human body Suitable for indoor outdoor 1 This sensor is equipped with an AND detection and pulse count system 2 The AND detection system will issue an alarm signal only when detection occurs in both horizontal and downward zones simultaneously 3 The sensor is equipped with many features such as Alarm output control depending on the illuminance of the surrounding area Á Output time delay switch se...

Страница 2: ...esn t output signal This sensor operates during detecting time delay time set by a potentiometer It continues to issue alarm as long as it detects objects regardless of set delay time Do not pour water on this unit with a hose as it is designed to be rainproof not waterproof When detection mode is set at AND mode this sensor outputs alarm signal only when both upper and lower sensor detect objects...

Страница 3: ...OP VIEW Wall Detection DETECTION MODE OR Fine Adjustment 3 3 3 3 Masking unnecessary zones Variable range Downward zone 10m 33 10m 33 5m 16 5 5m 16 5 0 Detection distance is set by adjusting the angle of downward zone Adjusting range 10 3m to 40 12m 7 ranges Detection distance is set by adjusting the angle of downward zone Adjusting range 10 3m to 40 12m 7 ranges The detection zone of this unit co...

Страница 4: ...ment Detection distance can be adjusted within a range from 10 3m to 40 12m by turning the angle of downward zone vertically Refer to the index and slide the adjustment lever up or down Slide it up and the detection distance becomes shorter sliding it down detection distance becomes longer Detection distance depends on how the sensor is installed and how its sensitivity adjustment is set Area mask...

Страница 5: ...e can be adjusted between 2sec and to 5min approx Delay time ON OFF ON OFF Factory set ON 1a 1b OFF a N O b N C Factory set Less sensitive prevents false alarms caused by temperature fluctuation More sensitive ON OFF ON OFF Factory set Lights at alarm LED disabled During warm up period light flickers ON OFF AND OR Factory set Alarm signal is issued only when both upper and lower sensors detect obj...

Страница 6: ... when two or more sets are connected is the value above divided by number of sets 2 The signal line can be wired to a distance of up to 3 000ft 1 000m with AWG 22 dia 0 65mm telephone wire 3 Wire Insertion Break one outside knockout and its related inside knockout as necessary Pull wire through the insertion holes and connect it to the terminals Break inside knockout pull wire through wiring hole ...

Страница 7: ...stment 1 Readjust the protection area setting 2 Improper operation mode setting 2 Readjust operation mode setting 3 Cover face is soiled with dust or water drop 3 Clean the cover with soft cloth 4 Area covered by both upper and lower sensor is too small to be 4 Readjust the sensor angle detected when set at AND mode Only applicable to MS 12FE Activated when no 1 Unstable power voltage 1 Stabilize ...

Страница 8: ... to 122ºF 20ºC to 50ºC Mounting position Indoor Outdoor Height 0 8 1 2m Weight 13 7oz 390g 16 5oz 470g Appearance Body AES resin Lens PE resin Accessory Tapping screw 2 Tapping screw 2 Area masking sheet 1 Area masking sheet 2 Optional Wall mount attachment BW 24 Pole attachment BP 22 TAKEX Europe Limited Aviary Court Wade Road Basingstoke HANTS RG24 8PE UK Tel 44 0 1256 475555 Fax 44 0 1256 46626...