1. Terminal Configuration
2. Wiring distance
SUPPLY VOLTAGE
•
12V to 30VDC (Non Polarity)
•
Power consumption
35mA MAX (MS-12TE)
40mA MAX (MS-12FE)
OUTPUT SIGNAL
Dry contact relay output form N.O/N.C selectable
CONTACT OPERATON
Detection time + off delay (2sec.-5min. approx.)
CONTACT CAPACITY
30V (AC/DC), 0.5A MAX. (resistive load)
DAY LIGHT
Output operates when daylight is below setting.
TAMPER
•
Dry contact relay output N/C
CONTACT CAPACITY
30V (AC/DC), 0.5A MAX. (resistive load)
WIRE SIZE
AWG24 ~ AWG14 (0.2mm
2
) ~ (2mm
2
)
Exposed wiring
Mounted wiring
Power voltage
DC12V
DC24V
0.3mm
2
(ø0.65mm)
820’ (250m)
8,500’ (2600m)
0.5mm
2
(ø0.8mm)
1,480’ (450m)
14,100’ (4300m)
0.8mm
2
(ø1.0mm)
2,300’ (700m)
21,300’ (6500m)
1.2mm
2
(ø1.25mm)
3,120’ (950m)
29,500’ (9000m)
Note: 1) Maximum wiring distance when two or more sets are
connected is the value above divided by number of sets.
2) The signal line can be wired to a distance of up to 3,000ft.
(1,000m) with AWG 22 (dia. 0.65mm) telephone wire.
3. Wire Insertion
•
Break one outside knockout and its related inside knockout
as necessary.
Pull wire through the insertion holes and connect it to the
terminals.
•
Break inside knockout,
pull wire through wiring
hole and connect it to the
terminals.
* When installing the sensor
to flush mount box, use
wall mount bracket (BW-
24) [sold separately].
Outside
knockout
Inside
knockout
Wiring
hole
Wiring
box
Outside
knockout
(1) Read PRECAUTIONS (3) before installation.
(2) Loosen cover locking screw and detach cover.
(3) Refer to WIRING (6) and connect wires to the terminal.
(4) Install the unit.
(5) Refer to DETECTION
AREA (4) and OPERATION
CHECK (8) and check
detection area and operation.
(6) Replace the cover.
Power
Cover locking screw
Contact output
Tamper
Size of wire