background image

Option: Glass checker EG-2000

1.26

(32)

1.77

(45)

7.87

(200)

Knockout

Knockout

Knockout

2.92

(74.2)

2.62

(66.5)

5

2

(51)

0.47

(12)

0.17

(4.5)

0.17

(4.5)

0.47

(12)

1.14

(29)

R0.8

(R2.1)

R0.8

(R2.1)

φ

0.16

(

φ

4.2)

φ

0.16

(

φ

4.2)

3.29

(83.5)

2.63

(66.7)

Lock screw

Limited Warranty :

TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover 
damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided 
by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in 
duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective 
parts returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be 
charges rendered for product repairs made after our Warranty Period has expired.

No.05-991   1708

In Japan

Takex America Inc.

4/15 Howleys Road, Notting Hill,
VIC, 3168
Tel  : +61 (03) 9544-2477
Fax : +61 (03) 9543-2342

Takenaka Engineering Co., Ltd.

83-1, Gojo-sotokan, 
Higashino, Yamashina-ku, 
Kyoto 607-8156, Japan 
Tel  : 81-75-501-6651
Fax : 81-75-593-3816
http : // www. takex-eng. co. jp /

Takex Europe Ltd.

Takex House, Aviary Court, Wade Road,
Basingstoke, Hampshire. RG24 8PE, U.K.
Tel  : (+44) 01256-475555
Fax : (+44) 01256-466268
http : // www. takexeurope. com

In the U.S.

In the U.K.

In Australia

Takex America Inc.

151 San Zeno Way 
Sunnyvale,
CA 94086, U.S.A
Tel  : 408-747-0100
Fax : 408-734-1100
http : // www. takex. com

12

EXTERNAL DIMENSIONS 

  (Unit : mm)

Содержание GS-2000E

Страница 1: ... wood such as plasterboard or concrete use the anchors and mounting screws appropriate to the wall materials and install the unit securely Unstable installation may result in injury or damage to property if the unit falls down Fix the sensor unit for operation using the lock screws This prevents injury and or damage to property if the unit falls down and also prevents the unit from being scratched...

Страница 2: ... breaking sound generated when plate glass is broken on impact It cannot detect broken glass damaged by a force other than impact such as deformation of buildings structures Caution Do not apply impact to the unit Applying strong impact to the unit may result in deteriorated performance and or damage to the unit Install the sensor at a place where the glass surface to be guarded can be seen direct...

Страница 3: ...ront direction Sensor mounting position For open wiring before mounting the base unit break the knockout on the base unit and pass the wire through the opening Mount the sensor max two meters from the glass surface In a curtain box mount the sensor so that the operation area is not blocked Do not mount the sensor in a curtain box that is too deep to avoid masking the protection area Mount the sens...

Страница 4: ...s Maximum allowable wiring distance between the sensor and power equipment Basic connection connection example when using multiple units Distance between wall and sensor Distance between ceiling and center of glass Area adjustment angle from 0 to 30 Center of the area Area selector Indicator Front mark 0 30 The detection area has a spread Set the area so that the center of the detection area is ro...

Страница 5: ...f a warning is given immediately check operation of the sensor Check mode Operation mode This mode is used to check the installation environment and the sensitivity Press the check mode switch to activate Check mode for approximately five minutes While in this mode the alarm indicator red blinks at short intervals In this mode both the environmental indicator orange and alarm indicator red can be ...

Страница 6: ...nsor unit from the glass surface to be protected and check the sensitivity Check it from all the positions of the glass surface to be protected Note Reliable use of the glass checker is difficult under the influence of adverse reflection from ceilings walls and or floors If this is the case move the glass checker position slightly to the left or right and check again If only the environmental indi...

Страница 7: ...oltage 2 Remove the blocking materials 3 Set the appropriate sensitivity Refer to 8 Function Description The unit remains in check mode not switching to operation mode 1 There are noise sources bells ultrasonic sensors printers or devices that generate metallic sound near the unit 1 Remove items causing malfunction or keep them apart from the unit three meters or more The unit sometimes does not o...

Страница 8: ... shipment During the Warranty Period TAKEX will repair or replace at its sole option free of charge any defective parts returned prepaid Please provide the model number of the products original date of shipment and nature of difficulty being experienced There will be charges rendered for product repairs made after our Warranty Period has expired No 05 991 1708 In Japan Takex America Inc 4 15 Howle...