Sensitivity is too low

Increase the sensitivity setting

In order to ensure reliable operation, use “Glass checker EG-2000” (sold separately), and check operation and sensitivity according to the following 
description. *Follow the instruction manual of the glass checker.

(4) If you activate the checker from the glass surface most distant to the 

sensor unit, and only the environmental indicator lights up, the sensitivity 
is normal. If the environmental indicator does not light up, the sensitivity 
is too low. On the contrary, if it lights up and the alarm indicator also 
lights up, the sensitivity is too high. If there are positions where the 
sensitivity is not appropriate, check the operation area again, or adjust the 
sensor sensitivity.

SENSITIVITY CHECK

Check the extension of the detection area, and the most appropriate sensitivity while checking that the environmental indicator on the sensor unit 
lights up.
Set the sensitivity setting inside the EG-2000 to “L” side, and use the checker.

Check operation of the installed sensor unit.
Use this function only for the daily operation check of the sensor, or during 
inspection.
Set the output switch inside the EG-2000 to “H” side, and use the checker.

(1) Turn on the sensor power. Press the check mode switch to 

activate “Check mode” for approximately five minutes, 
and the alarm indicator blinks. “Check mode” is extended 
by approximately five minutes for every detection 
operation (alarm indicator lights up). Refer to “8. 
Function”

(2) First, press the send button on the glass checker to 

activate near the sensor unit. Check that both the alarm 
indicator (red) and environmental indicator (orange) light 
up.

(3) Activate the glass checker by pointing its transmission 

section toward the sensor unit from the glass surface to 
be protected, and check the sensitivity. Check it from all 
the positions of the glass surface to be protected.

Note: Reliable use of the glass checker is difficult under 

the influence of adverse reflection from ceilings, 
walls, and/or floors. If this is the case, move the 
glass checker position slightly to the left or right, 
and check again. If only the environmental indicator 
on the sensor unit lights up, the sensitivity is 
normal.

Activate the glass checker by pointing its transmission section toward 
the sensor unit from the sensor’s operation area, by pressing the send 
button.
If the alarm indicator lights up, and a device connected to the alarm 
output activates, the alarm operation of the sensor is normal.

If there is a possibility of sound and/or noise in the same space as the glass to be protected, generate actual sound and/or noise as a test, and 
check that the environment indicator does not light up. Refer to “8. Function”
If the environmental indicator lights up by sound or noise, change the installation location, or decrease the sensor sensitivity by increasing the 
number of the sensor units to be installed and by reducing the detection area per unit.

(5) If detection operation has not been performed for approximately five minutes 

after the sensitivity check finishes, the mode automatically switches to 
“Operation mode”. Check that the alarm indicator is not blinking before 
operation.

Environmental indicator

Alarm indicator

Environmental indicator

Alarm indicator

Operation area

Glass checker

ENVIRONMENT CHECK

Check whether the sensor installation environment is appropriate or not.

9

OPERATION CHECK

Environmental indicator : OFF
Alarm indicator 

: OFF

Sensitivity is normal

Environmental indicator : Light up
Alarm indicator 

: OFF

Sensitivity is too high

Decrease the sensitivity setting

Environmental indicator : Light up
Alarm indicator 

: Light up

ALARM OPERATION CHECK

Содержание GS-2000E

Страница 1: ... wood such as plasterboard or concrete use the anchors and mounting screws appropriate to the wall materials and install the unit securely Unstable installation may result in injury or damage to property if the unit falls down Fix the sensor unit for operation using the lock screws This prevents injury and or damage to property if the unit falls down and also prevents the unit from being scratched...

Страница 2: ... breaking sound generated when plate glass is broken on impact It cannot detect broken glass damaged by a force other than impact such as deformation of buildings structures Caution Do not apply impact to the unit Applying strong impact to the unit may result in deteriorated performance and or damage to the unit Install the sensor at a place where the glass surface to be guarded can be seen direct...

Страница 3: ...ront direction Sensor mounting position For open wiring before mounting the base unit break the knockout on the base unit and pass the wire through the opening Mount the sensor max two meters from the glass surface In a curtain box mount the sensor so that the operation area is not blocked Do not mount the sensor in a curtain box that is too deep to avoid masking the protection area Mount the sens...

Страница 4: ...s Maximum allowable wiring distance between the sensor and power equipment Basic connection connection example when using multiple units Distance between wall and sensor Distance between ceiling and center of glass Area adjustment angle from 0 to 30 Center of the area Area selector Indicator Front mark 0 30 The detection area has a spread Set the area so that the center of the detection area is ro...

Страница 5: ...f a warning is given immediately check operation of the sensor Check mode Operation mode This mode is used to check the installation environment and the sensitivity Press the check mode switch to activate Check mode for approximately five minutes While in this mode the alarm indicator red blinks at short intervals In this mode both the environmental indicator orange and alarm indicator red can be ...

Страница 6: ...nsor unit from the glass surface to be protected and check the sensitivity Check it from all the positions of the glass surface to be protected Note Reliable use of the glass checker is difficult under the influence of adverse reflection from ceilings walls and or floors If this is the case move the glass checker position slightly to the left or right and check again If only the environmental indi...

Страница 7: ...oltage 2 Remove the blocking materials 3 Set the appropriate sensitivity Refer to 8 Function Description The unit remains in check mode not switching to operation mode 1 There are noise sources bells ultrasonic sensors printers or devices that generate metallic sound near the unit 1 Remove items causing malfunction or keep them apart from the unit three meters or more The unit sometimes does not o...

Страница 8: ... shipment During the Warranty Period TAKEX will repair or replace at its sole option free of charge any defective parts returned prepaid Please provide the model number of the products original date of shipment and nature of difficulty being experienced There will be charges rendered for product repairs made after our Warranty Period has expired No 05 991 1708 In Japan Takex America Inc 4 15 Howle...

Отзывы: