Takex GS-2000E Скачать руководство пользователя страница 5

Mode selector

Use the mode selector inside the sensor unit to perform various settings.

ON  

Light up when the sensor activates 

 the 

alarm

OFF

Always off

DIP switch 1

ON

OFF

(factory set)

Alarm indicator setting (DIP Switch 1)

Set the alarm indicator (red) status.

DIP switch 3

ON

N.O.

OFF

N.C.

(factory set)

ON  

N.O.

OFF

N.C.

Alarm contact setting (DIP Switch 3)

Set the alarm contact to N.O. /N.C. 

Sensitivity setting (Dip Switch4,5)

Change detection sensitivity.

ON  

Noise reduction setting

   

Set to ON when there are many 

   

environmental noises.

OFF

Normal operation setting

DIP switch 6

ON

Noise reduction

setting

OFF

Normal

operation setting

(factory set)

Noise reduction setting (DIP Switch 6)

Reduce environmental noise.
*When this setting is ON, the detection distance could be shortened.

Make sure to check sensitivity before 
operation. (Refer to “9. Operation Check”)

ON  

When the sensor activates the alarm, the 
alarm indicator blinks for three minutes, 
and lights up for 47 minutes. (If the sensor 
activates the alarm again whilst the 
memory display is lit, the memory display 
will light up for a further 47 minutes.)

Memory OFF

OFF

Memory display setting (DIP Switch 2)

Set the memory display status.

ON

Auto reset

memory

(factory set)

No memory

function

DIP switch 2

OFF

SELF-DIAGNOSIS FUNCTION

TAMPER FUNCTION

This function monitors whether the sensor unit is mounted 
properly or not, and also gives a warning against action related to 
the main body removal. If the sensor unit is removed, or mounted 
improperly, the tamper output is generated for warning. When the 
sensor unit is remounted properly, the function is restored. If a 
warning is given, immediately check operation of the sensor.

Function description

Factory set

ON

OFF

1 2 3 4 5 6 7 8

*Make sure to keep DIP switches 7 and 8 OFF during operation.

This function monitors whether any damage or disconnection occurs in 
the sensor circuits or not.
If any damage or disconnection occurs inside the unit, a warning is 
given using the alarm output and alarm indicator.
If you reset the sensor power during a warning, monitoring temporarily 
stops, but it restarts when the warming-up operation finishes.
If a warning is given, immediately check operation of the sensor.

Check mode

Operation mode

This mode is used to check the installation environment, 
and the sensitivity. Press the check mode switch to 
activate “Check mode” for approximately five minutes.
While in this mode, the alarm indicator (red) blinks at 
short intervals. In this mode, both the environmental 
indicator (orange) and alarm indicator (red) can be 
operated. Even if the alarm is set off, the memory 
function will not activate. “Check mode” is extended by 
approximately five minutes for every detection (alarm 
indicator lights up).

This is normal detection mode. After check mode finishes, 
it is automatically switched to operation mode.
If the sensor activates the alarm, the alarm indicator 
(red) activates the memory display for 50 minutes (auto 
reset after blinking for three minutes, and being lit up for 
47 minutes). Note that the environmental indicator 
(orange) does not operate.

*When the memory display setting is set to ON.

*Even if this is set to OFF, the 

indicator lights up in check mode, 
and when the malfunction occurs.

CHECK MODE FUNCTION

This function is used to check the installation environment and the sensitivity.
The surrounding environment where the sensor is installed can be confirmed. If there are sound sources or noise that may 
cause a false alarm in an installation environment, it notifies by the environmental indicator lighting up.
When the ‘Check mode switch’ is pressed, it switches over to ‘Check mode’ for five minutes. It enables checking of the 
detection area. 
(Refer to “9. Operation Check”)
If the sensor does not detect anything for approximately five minutes, “Operation mode” is set automatically. Note that 
“Check mode” is extended by approximately five minutes for every detection (indicator lights up). To activate “Check mode” 
again, press the check mode switch.

Activation of the glass 
checker or noise sound 

Environmental indicator
(orange)
Alarm indicator
(red)
Alarm output

Sensitivity

is high

Sensitivity

is low

Sensitivity

is good

Adjustment

ends

Noise test 

passed

Environmental noise

Noise test 

failed

Noise test 

failed

Checker

Checker

Checker

Glass breaking sound

Environmental indicator
(orange)

Alarm indicator
(red)

Alarm output

47 min.

47 min.

(retriggered)

Approx. 2 sec.

Blinking for 3 min.

8

FUNCTION

ON

OFF

(Factory set)

DIP switch 4,5

High

Low

Содержание GS-2000E

Страница 1: ... wood such as plasterboard or concrete use the anchors and mounting screws appropriate to the wall materials and install the unit securely Unstable installation may result in injury or damage to property if the unit falls down Fix the sensor unit for operation using the lock screws This prevents injury and or damage to property if the unit falls down and also prevents the unit from being scratched...

Страница 2: ... breaking sound generated when plate glass is broken on impact It cannot detect broken glass damaged by a force other than impact such as deformation of buildings structures Caution Do not apply impact to the unit Applying strong impact to the unit may result in deteriorated performance and or damage to the unit Install the sensor at a place where the glass surface to be guarded can be seen direct...

Страница 3: ...ront direction Sensor mounting position For open wiring before mounting the base unit break the knockout on the base unit and pass the wire through the opening Mount the sensor max two meters from the glass surface In a curtain box mount the sensor so that the operation area is not blocked Do not mount the sensor in a curtain box that is too deep to avoid masking the protection area Mount the sens...

Страница 4: ...s Maximum allowable wiring distance between the sensor and power equipment Basic connection connection example when using multiple units Distance between wall and sensor Distance between ceiling and center of glass Area adjustment angle from 0 to 30 Center of the area Area selector Indicator Front mark 0 30 The detection area has a spread Set the area so that the center of the detection area is ro...

Страница 5: ...f a warning is given immediately check operation of the sensor Check mode Operation mode This mode is used to check the installation environment and the sensitivity Press the check mode switch to activate Check mode for approximately five minutes While in this mode the alarm indicator red blinks at short intervals In this mode both the environmental indicator orange and alarm indicator red can be ...

Страница 6: ...nsor unit from the glass surface to be protected and check the sensitivity Check it from all the positions of the glass surface to be protected Note Reliable use of the glass checker is difficult under the influence of adverse reflection from ceilings walls and or floors If this is the case move the glass checker position slightly to the left or right and check again If only the environmental indi...

Страница 7: ...oltage 2 Remove the blocking materials 3 Set the appropriate sensitivity Refer to 8 Function Description The unit remains in check mode not switching to operation mode 1 There are noise sources bells ultrasonic sensors printers or devices that generate metallic sound near the unit 1 Remove items causing malfunction or keep them apart from the unit three meters or more The unit sometimes does not o...

Страница 8: ... shipment During the Warranty Period TAKEX will repair or replace at its sole option free of charge any defective parts returned prepaid Please provide the model number of the products original date of shipment and nature of difficulty being experienced There will be charges rendered for product repairs made after our Warranty Period has expired No 05 991 1708 In Japan Takex America Inc 4 15 Howle...

Отзывы: