220
OPTIONS
Air Conditioner
Replace
Replace the belt in the following cases:
• If it stretches and its tension cannot be
adjusted.
• If it is cut or cracked.
• If the fan belt is worn and the pulley is
touching the bottom of the V groove.
Cleaning the Filters
Clean the filters sooner when operating in
dusty places.
If the filters are clogged, the air becomes
weak and a muted booming sound is heard
from the air conditioner unit.
Removing the filters
1. Loosen the bolts (1) and remove the cover
(2).
2. Remove the inner filter (3).
3. Loosen the bolts (4) and remove the cover
(5).
4. Remove the outer filter (6).
5. Use compressed air to clean the filters.
Cleaning
CAUTION
Wear safety glasses when using
compressed air.
1. Blow dry, compressed air (138 kPa or 20
psi or less) directly on the filter from the
inside, moving up and down along the
creases.
Be sure to keep the nozzle at an adequate
distance from the filter.