3-5 R eplacement of S ens or probe bas e CS 8000-S 21
3 - 15
The information on how to replace Sensor probe base CS8000-S21 is described below.
How to remove
1. Pull out the CS8000-S21 straight.
(NOTE) Never try to pull it in an oblique direction
so hard the sensor probe is bent.
CAUTION
Once the CS8000-S21 is pulled out of the sensor probe, usually the springs is extended so that they can
#
t
reuse it any more. Also, pay much attention to the mounting direction (See below).
How to install
1. Fit the CS8000-S21 in the pins at the sensor probe after faced its green side in the direction where the
cable hole is. (Refer to Fig.-1,2)
2. Push up the CS8000-S21 straight tightly. (Refer to Fig.-3)
(NOTE) When you do not go to the prescribed distance (1.5 ~ 2.5mm) or the CS8000 is installed with some
inclination, it has not been all the way seated. (Refer to Fig.-4)
Fig.-1
Fig.-2
Fig.-3
Fig.-4
Push up
1.5 ~ 2.5mm
Senor probe base
CS8000-S21
Green
Inclined
Pin
Cable hole
Sensor probe
Senor probe base
CS8000-S21