background image

■Neck cushion

Caution 

At the end of work each day, wash the neck cushion with water, wipe them dry with a towel, and allow

them to dry in the shade.

If they are extremely dirty, wash with detergent diluted with water, and rinse carefully with

water.

The neck cushion is a consumable supply. Replace it if it is extremely dirty or the

surface has deteriorated.(available at additional cost)

● If solvents drip onto the neck cushion, rinse with water as soon as possible.

Failure to follow this instruction may cause deformation or discoloration.

● Clean the neck cushion every day. Leaving dirt uncleaned may cause them to get

moldy.

19

■Showerhead

1

Caution

Be careful not to pinch your hand or finger in
the wrench.

2

Rotate and loosen the air bubble fixture with the wrench.

3

Caution

The air bubble unit should be rinsed with running water
in the direction shown in the illustration below:

Running Water

Air Bubble Unit

4

After cleaning, set the three parts in the order shown in the

illustration.

5

Tighten the air bubble fixture with the wrench.

This completes the cleaning.

Wrench

Rubber Gasket

Air Bubble Fixture

Air Bubble Unit

Loosening

Tightening

The air bubble unit and the gasket can be reused after washing with water. 
If replacements are required due to deterioration or breakage, however, contact your closest dealer.

The air bubble area of the showerhead should be cleaned

once a month (as a general guide). Apply the supplied

wrench to the chamfered portion of the air bubble fixture.

Remove the three parts (rubber gasket, air bubble unit, and

air bubble fixture) and wash with water using a nylon or

similar brush.

Содержание RS SWING

Страница 1: ...Thank you for purchasing this Takara Belmont product The instructions contained in this booklet should be thoroughly read and understood before use Using this product before reading this operating ma...

Страница 2: ...responsible for any damage or risk incurred Detailed descriptions of symbols are provided below Read and understand these symbols thoroughly before reading this manual Symbols If this symbol is ignor...

Страница 3: ...cution fire or abnormal operation leading to injury Disassembly and repairs modifications are prohibited Return the temperature control knob to an appropriate position after using hot water Return the...

Страница 4: ...rounding area and turn the water control knob slowly Do not drink the hot water This product is designed for washing hair Do not drink the hot water The water quality may cause diarrhea or stomach pai...

Страница 5: ...sunlight or heat from a stove Avoid direct sunlight or heat from a stove Failure to follow this instruction may cause discoloration or degradation of the product Do not leave the showerhead immersed i...

Страница 6: ...n may cause flaws on the surface or breakage of the neck cushion Set the water temperature for this product to 80 or less Failure to follow this instruction may cause malfunction or breakage in parts...

Страница 7: ...nd the basin when the backrest is reclined may vary slightly from product to product 1 Back shampooing the user stands behind the basin and performs shampooing from the back back position 7 Position o...

Страница 8: ...eel due to corrosion or aged deterioration Flaws or cracks may occur on the plated surface due to impacts from falling objects Flaws or cracks may occur on the plated surface when a hard object hits t...

Страница 9: ...fixing pins are detachable Be careful not to lose them 3 While shaping the neck cushion along the basin edge secure the hooks of the neck cushion to the fixing pins on the outer side of the basin Cha...

Страница 10: ...immediately stop using the product and contact the nearest dealer or Takara Belmont directly The drain pipe may be clogged with dirt resulting in water leakage of the inside of the product Operate th...

Страница 11: ...or a lack of grease as a result of aging Replacement of the packing or other parts or a recoating of grease is required available at additional cost Caution 1 Turn the temperature control knob in the...

Страница 12: ...osition of the temperature control knob is adjusted Note Caution Return the temperature control knob to an appropriate position after use Continuing to use the hot water with the knob in the hot tempe...

Страница 13: ...slows there is a possibility that dust and dirt may have clogged the drainpipe Immediately stop using the product and contact your closest dealer To fill up basin with water 1 To accumulate hot water...

Страница 14: ...s fully swung to its maximum until it stops moving and fixes Failure to follow this instructions may make the basin to move during shampooing causing leakage or wetting client s clothes 3 Adjust the s...

Страница 15: ...ating shower head However water may drop to the floor depending on the shampooing way Please take note of the followings when performing shampooing 1 Do not touch the client hair with the shower head...

Страница 16: ...fter shampooing raise the chair backrest while supporting the client s head by your hand Caution Always support the client s head by your hand when raising the chair backrest 6 Swing back the basin to...

Страница 17: ...l nail polish remover gasoline or kerosene cleaning products such as wax with a scourer a sponge with a scourer detergents that include organic solvents acidic alkaline or chlorine based detergents or...

Страница 18: ...shampoo Showerhead Holder Tap Temperature Control Knob Wipe off the dirt with a soft cotton or towel with detergent solution diluted using water Caution Even when using a sponge for home use continuou...

Страница 19: ...Rotate and loosen the air bubble fixture with the wrench 3 Caution The air bubble unit should be rinsed with running water in the direction shown in the illustration below Running Water Air Bubble Un...

Страница 20: ...ply pipe When removing maintenance cover and plumbing cover pay attention those parts will not hit the rotation arm cover 4 When the strainer is detached the water in the pipe will come out Therefore...

Страница 21: ...n unit or pipes in the rotat ion arm may be damaged so contact the nearest dealer or Takara Belmont directly Stop Valve Knob Open the Stop Valve at the beginning of the day and close it at the end of...

Страница 22: ...se Replace every three years For the drain hose there is a possibility that water leaks will occur because cracks are caused due to deterioration and hardening of the hose from chemical agents in the...

Страница 23: ...rs Consumable Parts The following parts are not covered by the wa rranty the cost of replacement is your responsibility Drain cap Hair catcher Rubber gasket etc Air Bubble unit of showerhead air bubbl...

Страница 24: ...ly pressure Difference between hot water supply pressure and water supply pressure Within 0 2 MPa 2kgf cm2 Operating environment Operating temperature 10 40 Operating humidity 95 or below No condensin...

Страница 25: ...neck cushion 676 Shampoo basin mounting surface 977 497 428 887 650 90 52 470 951 885 325 522 228 Chair side Center of Drain pipes Center of rotation 922 639 228 162 400 600 Pitch 1200 112 5 Operating...

Страница 26: ...at there is no abnormal noise then close the water control knob and check that warm water stops properly If there is abnormal noise or the water does not turn off properly when the water cotrol knob i...

Страница 27: ...ion degraded Check that there is no tearing dirt or sinking of the neck cushion surface These may cause pain or transfer dirt to the customer s neck and head The neck cushion is consumable supplies Re...

Страница 28: ...28 1E0511A0 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Отзывы: