25
Precision screw driver(-)
Tap
Open
Tap cap
Pan head self tapping
screw [4×16]
Plastic bag
Temperature
control handle
Temperature control handle
Centre plane
Red line
If water temperature is high
<Double tap type>
1. Turn the tap on anti-clockwise at the maximum degree.
2. Turn the temperature control handle up to the lock position,
and measure the water temperature.
3. Remove the cap and screw from temperature control
handle, and take the handle out of the unit.
If you use a precision screwdriver or other
metallic tool to remove the cap, cover the cap
with a plastic bag beforehand.
Make sure the tool does not scratch the coated
surface of the temperature control handle and
the cap.If the coated surface gets scratched,
broken or peeled, contact your closest dealer.
The damaged coated surface might cause injury
while in use of the equipment.
Caution
4. Adjust the position of the conversion adaptor
Ƒ
If the measured temperature was higher than 40
℃
ĺ6KLIWWKHFRQYHUVLRQDGDSWRUDQWLFORFNZLVH
and fix it on to the thermostat.
Ƒ
If the measured temperature was lower than 40
℃
ĺ6KLIWWKHFRQYHUVLRQDGDSWRUFORFNZLVH
and fix it on to the thermostat.
Caution
When adjusting the conversion adaptor, adjust in small
increments, otherwise it can result in a high flow of hot
water, which may result in burns or scalds
5. Attach the temperature control handle to the conversion
adaptor, and check if the water temperature is
approximately 40
℃
at the lock position.
Ƒ
If it is not approximately 40
℃
ĺ5HSHDW³´
6. Fix the temperature control handle and the conversion adaptor
with the screw.
7. Place the cap on the temperature control handle.
If water temperature is low