Always test the water flow to prevent accidents during use.
23
Testing the unit
12
Shower head
Ŷ
Test water flow
1
Ŷ
Cleaning
2
Packing
Aerator core
Close
Open
Wrench
Filter
Wrench
Close
Open
Open
Close
Wrench
Stop valve
Remove the aerator core and
clean inside
Remove any trapped dirt and clean the shower head
<Single tap type>
<Double tap type>
̅7HVWWKHZDWHUIORZDQGLQVSHFWWKHIROORZLQJLWHPV7KHKRWZDWHUPD\EHVOLJKWO\WDLQWHGDWWKHVWDUW
of the water flow test, however, this does not indicate any problem.
1. Is there no water leaking from the pipe joints?
2. Are the hot water supply and water supply pressures in the appropriate range? (See page 5 )
If the pressures are not in this range, see ”How to adjust faulty temperature regulation” below this page.
3. Can temperature be controlled properly?
If not, see page 24, 25 and set up the temperature control handle
4. Check that the shower outlet flow is sufficient, by the following as a guide for flow rate.
Shower outlet flow rate: <Single tap type> Approximately 16L/min
<Double tap type>Approximately15L/min
ż
After the hot water becomes clear during the water
flow test, always clean the filter (within the stop cock)
and shower head.
Failure to do so can result in insufficient flow rate and
faulty temperature regulation. During the cleaning,
ensure not to damage or lose the packings.
Caution
Caution
How to adjust faulty temperature regulation
ż
Contents of defect
ż
Presumed cause
ż
What to do
1. Temperature is unstable.
2. Hot water(high temperature) does not come out.
3. Water(low temperature) does not come out.
1. The difference between water supply and hot-water supply pressure is not
in the appropriate range, or the pressure of hot water supply is higher
than the pressure of water supply.
[water supply
Ӎ
ᴾ
hot water supply (The difference should be in the range of 0.2MPa)]
2. Pressure of water supply and hot water supply is high
[These two should be in the range between 0.1 and 0.4MPa(1
〜
4kgf/cm )]
Connect a pressure reducing valve (not include) in order to adjust the pressure.
(It is recommended that water supply pressure and hot water supply pressure are equal.)
Stop valve
Filter
2
Содержание MAJOLICA PORTO AY-SB P1
Страница 27: ...27 Memo...