WARNING FOR INSTALLATIONS
FOR YOUR SAFETY, READ BEFORE INSTALLATION:
Do not have the vent terminal pointing toward
any opening into a building. Do not locate your
heater in a pit or location where gas and water
can accumulate.
Do not install this water heater under an
overhang less than 3 ft. from its top or eaves.
The area under an overhang must be open to
three sides (Outdoor models only).
Do not install the water heater vent terminator
within 1 ft. in the USA of any air intake or building
opening, and within 3 ft. in Canada of any air
intake or building opening (Outdoor models
only, refer to p. 16).
Do not install next to a dryer or any source
of airborne debris that can be trapped inside
the combustion chamber, unless the system is
direct-vented.
Prohibited
Do not install the heater where water, debris or
flammable vapors may get into the flue terminal.
This may cause damage to the heater and void the
warranty.
Prohibited
1 ft. (305 mm) USA
3 ft. (914 mm) Canada
1 ft. (305 mm) USA
3 ft. (914 mm) Canada
1 ft. (305 mm) USA
3 ft. (914 mm) Canada
3 ft.
(915 mm)
Installation
Installation Manual
Water heater vent terminator must be at least 2
ft. (610 mm) away from an inside corner for both
outdoor installation and direct-vent installation.
Inside
Corner
2 ft.
(610 mm)