27
Page
CASE 3: Wrong connections between the "CHILD-1" unit and the "CHILD-2" unit
CASE 4: Remote controller connected to incorrect unit
Connecting two
“PARENT”
connectors together from two separate units
may
damage the computer board
. The communication cable has a female end and
a male end so it’s impossible to have a PARENT-to-PARENT connection with the
communication cable. Do not splice or modify connectors.
WARNING
Installation
Installation Manual
•
If you connect the
“PARENT”
connector of the
“CHILD-1”
unit to the
“1”
connector of the
“CHILD-2”
unit, the
“CHILD-2”
unit will operate as an individual unit, and will not be part of the
Easy-Link System.
Prohibited
Wrong connections between
the
"CHILD-1"
unit and the
"CHILD-2"
unit
Communication
cable
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
PARENT
unit
CHILD-1
unit
CHILD-2
unit
Wrong connection
Communication
cable
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
PARENT
unit
CHILD-1
unit
Wrong
connection
•
If a remote controller is used, it has to be connected to the
“PARENT”
unit. If the remote
controller is connected to a
“CHILD”
unit, it will only control that particular individual
“CHILD”
unit and will not control the Easy-Link System as a whole.
Prohibited
Remote controller
connected to
incorrect unit