(C) Examples of incorrect settings and /or connections
CASE 1: Wrong DIPswitch setting on the "PARENT" unit
CASE 2: Wrong connections between the "PARENT" unit and the
"CHILD-1" unit
Installation
Installation Manual
•
Unless you change DIPswitch No. 1 of the
“PARENT”
unit to the “ON” position, the system will
not work as an Easy-Link System. The units will operate as individual units.
Communication
cable
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
PARENT
unit
CHILD-1
unit
Wrong setting
Prohibited
Wrong DIPswitch
setting on the
“PARENT”
unit
•
A remote controller is not required for an Easy-Link System, however, it does
provide for more temperature options and ease of maintenance.
•
If running the Easy-Link System without a remote controller, please make
sure the temperature settings on ALL the units are set to the same settings.
Otherwise, the units will not operate properly.
•
If a remote controller is used, the temperature on all the units in the system
will automatically be set to the same temperature that is set on the remote.
NOTICE
Communication
cable
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
PARENT
unit
CHILD-1
unit
Wrong connection
Communication
cable
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
Connectors
Right bank of
Dipswitches
OFF
ON
1 2 3 4 5 6
PARENT
1
2
PARENT
unit
CHILD-1
unit
Wrong connection
OR
•
If you connect the
“1" (or "2")
connector of the
“PARENT”
unit to the
“PARENT" (or "1")
connector of the
“CHILD-1”
unit, the system will not work as an Easy-Link System. The units will
operate as individual units.
Prohibited
Wrong connections between the
"PARENT"
unit and the
"CHILD-1"
unit