![Takagi Flash Water Heater T-KD20 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/takagi/flash-water-heater-t-kd20/flash-water-heater-t-kd20_installation-manual-and-owners-manual_814322002.webp)
- 2 -
Table of Contents
Specifications……………………………..
2
For Your Safety…………………………...
3
Operation………………………………….
4
General…………………………… 4
Turning It On………………………
4
Turning It Off………………………
4
Temperature……………………… 4
Flow……………………………….. 4
Freeze
Protection………………... 5
Installation…………………………………
6
General…………………………… 6
Accessories………………………. 6
Electrical
Connections…………... 6
Wiring Diagrams………………….. 7-8
Gas Supply Piping……………….
9
Water
Plumbing………………….. 10
Pressure Relief Valve…………….
10
Wall Hanging Installation………...
11
Standing
Installation……………... 11
Installation…………………….…... 11
Combustible Air Supply and
Ventilation………………. 11
Combustion
air
supply… 12
Manufactured Home (Mobile Home)
Installation……………….………... 12
Initiating the Appliance
……... 12
Initial Operation
…………………... 12
Maintenance……………………
13
Troubleshooting……………….. 13-14
Applications…………………………..……. 15
Space Heating Application……….. 15-16
Storage Tank……………………...
17
Recirculation……………………… 17
For Your Safety………………………
18
Danger ……………………………..
19
Electrical Diagram……………………
20
Optional Items…………………………….
21
TK-RE01………………………….. 21
TK-BK01………………………….. 21
TK-TV01…………………………... 21
TK-TV03…………………………... 21
Dipswitch Settings………………………...
22
Indoor NG Dipswitch Settings…
22
Outdoor NG Dipswitch Settings….
22
Indoor LP Dipswitch Settings…
23
Outdoor LP Dipswitch Settings…
23
Exploded Diagrams………………………. 24-27
Parts List…………………………………..
28
Flow Chart………………………………..
29
Specifications
Natural Gas Input
Min. 20,000 Btu
Max. 185,000 Btu
LPG Input
Min. 19,000 Btu
Max. 175,000 Btu
Gas Connection
¾” NPT
Water Connections
¾” NPT
Water Pressure
Min. 15 psi
Max. 150 psi
Natural Gas Pressure Inlet Min. 5” WC
Max.
10.5”
WC
LP Gas Pressure Inlet
Min. 11” WC
Max. 14” WC
Manifold Pressure
Natural 2.3” WC
Propane 2.5” WC
Weight 60
lbs.
Dimensions 24.5”x16.5”x8.3”
Ignition Electronic
Ignition
Electrical Supply
AC 120 V
***
•
Inlet gas pressure must not exceed the
above maximum values.
•
For gas pressures lower than 5” WC for
natural gas and 14” WC for liquid Propane
gas, call the Gas Supplier.
•
Check the rating plate to insure this
product matches your specifications.
•
Takagi - USA is constantly improving our
products, therefore specifications are
subject to change without prior notice.
•
Содержание Flash Water Heater T-KD20
Страница 8: ...8 ...
Страница 20: ...20 ...
Страница 24: ...24 Computer board assembly ...
Страница 25: ...25 Case assembly ...
Страница 26: ...26 Burner assembly ...
Страница 27: ...27 Waterway assembly ...