![Takagi Flash Water Heater T-KD20 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/takagi/flash-water-heater-t-kd20/flash-water-heater-t-kd20_installation-manual-and-owners-manual_814322014.webp)
14
The T-KD20 Will Not Initiate
First check the flow rate through the unit. If the
flow is not .75 GPM or greater, the unit will not
initiate. Check the filter and the flow sensor for
any debris or damage.
Press the lower green button on the GFCI inside
the unit. If the red light above it does not come on,
then there is a problem with the electrical supply to
the unit. If that light does come on, hit the green
reset button above the light, and look for the green
light on the circuit plate at the top left of the unit. If
this light is not lit, there is a problem with the
electrical connection between the GFCI and the
circuit plate. Contact Takagi Industrial Company
for Instructions.
The T-KD20 Will Not Initiate
First check the flow rate through the unit. If the
flow is not .75 GPM or greater, the unit will not
initiate. Check the filter and the flow sensor for
any debris or damage.
Press the lower green button on the GFCI inside
the unit. If the red light above it does not come on,
then there is a problem with the electrical supply to
the unit. If that light does come on, hit the green
reset button above the light, and look for the green
light on the circuit plate at the top left of the unit. If
this light is not lit, there is a problem with the
electrical connection between the GFCI and the
circuit plate. Contact Takagi Industrial Company
for Instructions.
Error Codes
All Takagi units are self-diagnostic for errors. If
there is a problem with the installation or the unit, it
will give a signal, through a pair of flashing lights
on the circuit plate, to communicate the source of
the problem. If the unit has a TK-RE01 remote
control installed, this will give also give a numerical
error code. Consult the following chart for the
meaning of an error code:
T-KRE01
Computer Board
TK-RE01 Check
Point
11 Igniter
12 Flame
Detector
51
Main Gas Valve
Burning (red) LED: Blinking
Power (green) LED: OFF
72
Pre Post Check
03
Wrong Gas, Dip Switch
14 Hi-Limit
Switch
70 Computer
Board
Burning (red) LED: OFF
Power (green) LED: Blinking
71 Proportional
Valve
61 Fan
Motor
Burning LED and Power LED:
Blinking Alternately
21 Vent
Pipe
31 Thermistor
Burning LED and Power LED:
Blink Simultaneously
65
Water Control Valve
Содержание Flash Water Heater T-KD20