31
Page
Installation
Installation Manual
4. Tighten the two
"Fork terminals"
beneath the two
"Remote controller terminal"
screws on the back of
the main body.
(Fig. D-1)
5. Cut out the inlet for the remote controller cable
from the bottom of the main body.
(Fig. D-2)
6. Place the
"Main body"
back on the
"Back plate"
,
with the
"Remote controller cable"
running out of
the bottom inlet.
Remote controller
terminals
Fig. D-1
Two fork terminals
Remote controller cable
Inlet for the remote
controller cable
Cut out
Fig. D-2
Connecting the remote controller to the water heater
1. Disconnect power supply from the water heater.
2. Take off the water heater’s front cover.
3. Locate the two terminals for the remote controller in the water heater. (Refer to the
Fig. E-1
and
E-2
.)
4. Put the remote controller cable through the hole at the bottom of the water heater's casing from
outside.
5. Secure both terminals on the controller cable to the terminals in the cabinet as shown below.
(Secure them underneath the screw terminals. No polarity.) See Figures E-1 and E-2.
* Do NOT jump or short-circuit the wires, or the computer will be damaged.
6. Replace the water heater's front cover securely.
110U and 310U
100209924
(TM-RE42)
Front of remote
Connect other end to these terminals
Fig. E-1
100209924
(TM-RE42)
Front of remote
Connect other end to these terminals
510U
Fig. E-2