When the unit is not operated during the preset time, the unit is automatically shutdown.
Even if the user forgets to turn OFF the unit, this Shutdown function works to keep the
unit inactive, and prevents accidents such as fire.
4-5 Setting the Shutdown Function
CT
SUT
DIF
Power ON
Time
Soldering tip temperatrue
Operation
(Shutdown start time)
Power OFF
Sleep setting temp.
Set temperature
(Sleep start time)
DIF
(Sensitivity)
When using together with Sleep function.
SUT
Power OFF
So
ld
er
in
g
tip
te
m
pe
ra
tru
e
Set temperature
Power ON
Time
Operation
DIF
DIF
(Sensitivity)
(Shutdown start time)
1
2
4
Key Operation
TEMP Display
3
When SUT (Shutdown start time) value is set to 0, the shutdown function is OFF. The
display will alternate between Sdn and the temperature when the unit is in the shutdown
mode. The LED under the one digit on the TEMP window lights when the temperature
Example
: Changing the Shutdown start time
from 60 to 30. Unit : mins
Press and hold the
key
for over 3 seconds continuously.
Displays
alternately
Displays
alternately
Displays
alternately
Press the
key, until
the display changes to
30
.
Press and hold the
key
for over 3 seconds continuously.
Setting completed
Returns to the set
temperature display.
Press the
key five times.
Setting the Shutdown
start time (SUT)