background image

6

Unit

Solder Diameter

8) V-Groove Unit

0.5mm

0.6/0.65mm

0.8mm

1.0mm

1.2mm

1.6mm

FA-1000VU-05 FA-1000VU-06 FA-1000VU-08 FA-1000VU-10

FA-1000VU-12

FA-1000VU-16

9) Solder-Receiving Tube

Robot

0.5mm

0.6/0.65mm

0.8mm

1.0mm

1.2mm

1.6mm

200mm square

(50cm)

FA-1000VTB-

05-200

FA-1000VTB-

06-200

FA-1000VTB-

08-200

FA-1000VTB-

10-200

FA-1000VTB-

12-200

FA-1000VTB-

16-200

300mm square

(65cm)

FA-1000VTB-

05-300

FA-1000VTB-

06-300

FA-1000VTB-

08-300

FA-1000VTB-

10-300

FA-1000VTB-

12-300

FA-1000VTB-

16-300

400mm square

(70cm)

FA-1000VTB-

05-400*

FA-1000VTB-

06-400*

FA-1000VTB-

08-400*

FA-1000VTB-

10-400*

FA-1000VTB-

12-400*

FA-1000VTB-

16-400*

10) Clog-Detection Unit

0.5mm

0.6/0.65mm

0.8mm

1.0mm

1.2mm

1.6mm

FA-1000FDB-05

Solder Nozzle Tube

f

0.5 (1 pc) 

FA-1000FDB-06

Solder Nozzle Tube

f

0.6 (1 pc) 

FA-1000FDB-10

Solder Nozzle Tube

f

0.8 (1 pc) , 

f

1.0 (1 pc) 

FA-1000FDB-16

Solder Nozzle Tube

f

1.2 (1 pc), 

f

1.6(1 pc) 

Desktop Soldering System

FA-1000 Guide to Module Selection

 

(FA-3000 series)

Model

Optional Functions

Memory Card Reader / Writer

1-5 V Analog Voltage Output 

FA-1000

X

X

FA-1000-S2

O

O

FA-1000-S3

O

X

FA-1000-S4

X

O

FA-1000 is the product code of the Control 
Unit only.
To use the FA-1000 Soldering System, you will 
also need the Basic Units (see below) and a 
robot.
Memory Card Reader / Writer and 1-5 V 
Analog Voltage Output can be selected as 
optional functions.

1. Control Unit 

   

    

1) FA-1000

2. Basic Units

Data Logger (example)

Memory Card

(example)

Tip approaches targets obliquely.

Tip does not strike or mount terminals.

Without Diagonal Driver

With Diagonal Driver

2) Soldering Unit

FA-1000SD

3) Solder Feeder Unit

FA-1000FD

7) Diagonal Driver (Optional)

FA-1000SL

4) Solder Reel Holder

FA-1000RH1

(for 4-Axis)

FA-1000RH

(for 3-Axis)

5) Air Blow Tip Cleaner

FA-1000CL

6) Brush Tip Cleaner (Optional)

FA-1000BC

Removes burnt flux residue which cannot be 

removed by air blow.

FA-1000SL attaches to Soldering Unit 

FA-1000SD.

Provided that the tip does not interfere 

with components, you may choose the 

shorter stroke, giving a shorter cycle 

time.

*Tip not included.

* With 3-Axis robot, a 70cm tube must be used.

About Optional Functions

Memory Card Reader / Writer

You can save soldering configurations on memory cards.

Very useful to copy the data to other FA-1000 Control Units and also to backup.

1-5 V Analog Voltage Output

Tip temperature is output by 1-5 V analog voltage.

An off-the-shelf data logger would be helpful to monitor temperature control.

*Solder-Nozzle Tube included.

Содержание FA-1000 Series

Страница 1: ...taching the work to the jig Soldering Removing the work from the robot Assembling the work Attaching the work to the jig Detaching from jig Soldering Assembling the work Attaching the work to the jig Detaching from jig Better soldering operation time and quality Operator and robot divide the workand operate simultaneouslygHigh efficiency Lowercosts Does not rely on the operator s soldering skillsg...

Страница 2: ...sy Touch Panel English Japanese Chinese and Spanish Memory Card Function optional Multiple uses are easy and copiable by saving the data to the memory card Up to 6 Tip Temperature Settings Different tip temperatures can be set for each soldering RoHS 2 Compact tip with integrated heater gives accurate tip temperature and better running cost The direct heat effect from the heater is eliminated by m...

Страница 3: ...alized Sample Robot Configuration By combining with an unused robot a simple soldering robot can be constructed FA 3404 4 Axis Configuration Soldering System Calibration pin Calibration pin detects and corrects position of grooved tip Simple compact unit Insert new tip set up the unit and run the program Tip corrects automatically Added control axis max 4 axes 2 external axes Two motor controls ar...

Страница 4: ...t and easily installed on robots and devices Built in linear guide makes high precision soldering possible Stroke length 10mm Easier to replace tips with new improved mechanism Stepping motor controls feed amount precisely Solder wire diameter can be changed by replacing V groove unit Clog detection unit only Use convenient solder feeding knob to adjust position of solder feed Swappable gearbox ca...

Страница 5: ...ved spreading of solder wettability and cutting of solder A compact N2 station combining N2 generator and controller The special separation membrane separates the nitrogen from the compressed air produced by a compressor Tip Thermometer TM 100 Fume Vacuum SS 80AS Expendables Brush for Brush Tip Cleaner Air Blow Cleaner Filters Absorbs smoke generated during soldering work Air volume has 10 levels ...

Страница 6: ...de of the Control Unit only To use the FA 1000 Soldering System you will also need the Basic Units see below and a robot Memory Card Reader Writer and 1 5 V Analog Voltage Output can be selected as optional functions 1 Control Unit 1 FA 1000 2 Basic Units Data Logger example Memory Card example Tip approaches targets obliquely Tip does not strike or mount terminals Without Diagonal Driver With Dia...

Страница 7: ...e Program Capacity 255 999 Maximum Soldering Point 30 000 32 000 Model JANOME 3 Axis JANOME 4 Axis 11 Teaching Pendant 12 PC Software Option FA JRN PC FA JR3000 PC Model JANOME 3 Axis JANOME 4 Axis FA V2203 FA V2303 FA 3204 FA 3304 FA 3404 13 Robot Mounting Block 14 Fixing Plate for Air Blow Tip Cleaner FA V2203 FA V2303 FA 3204 FA 3304 FA 3404 FA 1000CLP1 FA 1000CLP2 FA 1000CLP1 FA 1000CLP2 Gate ...

Страница 8: ...5 FA 10HRT 3 2SD 7 0 2 6 ø4 2 1 2 1 8 15 6 FA 10HRT 1 2W HRT 3 2DV 30 3 ø4 2 5 15 FA 10HRT 4C 5 0 1 2 ø3 2 15 FA 10HRT 3 2D HRT 2 4D 40 40 7 0 ø4 2 0 8 4 0 4 0 1 4 1 8 15 FA 10HRT 0 8W 6 15 2 0 4 5 2 0 5 FA 10HRT 2PC 4 5 2 8 3 0 1 0 15 FA 10HRT 3PC HRT 3 2SD 7 0 2 6 ø4 2 1 2 1 8 15 6 FA 10HRT 1 2W 30 3 ø4 2 5 15 FA 10HRT 4C HRT 3 2D 40 40 7 0 ø4 2 0 8 4 0 4 0 1 4 1 8 15 FA 10HRT 0 8W 6 5 0 0 8 ø1 ...

Страница 9: ...connecting with interlock device such as area sensor Option COM1 Standard RC 232C for external device control COM commands COM2 Standard RC 232C for external device control 9 for connecting with FA 1000 COM3 Standard RC 232C for external device control MEMORY Standard For USB memory connection LAN Standard For PC connection via the Ethernet 10BASE T 100BASE TX Robot control via control commands Co...

Страница 10: ...JULY 2019 ...

Отзывы: