CHAPTER 4 SYSTEM MENU OPERATION
WETCUR
Description:
Wetting Current to Prevent line corrosion. The LINE selection of
STATUS [p.29] is unavailable [N/A] when user turns this selection
off. The wetting current selection is fully optional.
Options:
ON
Turn on the wetting current
OFF
Turn off the wetting current
RISING EDGE
Description:
DTE Transmit Data Signal Stage
Options:
NORMAL
Framer sets-up automatically
FALLING EDGE Force DTE transmit data is clocked at falling
edge
RISING EDGE
Force DTE transmit data is clocked at rising
edge
DISCONNECT
Description:
Disconnection Mode
Options:
AUTOMATIC
Disconnect according to the XSTREAM 1300
automatically
MANUAL
Disconnect if the disconnection button is
pressed. Time only is indicated.
TERMINATION
Description:
Terminal Impedance Match
Options:
HI-Z
140
Ω
LOW-Z
135
Ω
28