4.2.4. ALARM
The alarm function is to set the alarm notification to alert the operator. There are 2 sub-
menus under the ALARM mode.
v
ACTIVE ALARMS
If there is no alarm, the LCD display will show “No Alarms”. Otherwise, see table
for Alarm descriptions.
Table 4-2 ALARM messages and descriptions
HDSL ALARMS,
EQ-LIU#
DISPLAY
DESCRIPTION
LOOP-REV
Pairs crossed at RT side
T/R-REVERSAL
Transmitter Tip/Ring or Receiver Tip/Ring reversed
BOARD FAIL
CO or RT Board fail
HDSL ALARMS,
LP
DISPLAY
DESCRIPTION
T-BER
loop BER threshold crossed
T-SNR
loop SNR threshold crossed
T-PA
Pulse Attenuation threshold crossed
LOSW DEFECT
Loss of Sync Word defect
LOSW FAILURE
Loss of Sync Word failure
COFA
Change of Frame Alignment
LOS DEFECT
Loss of Signal defect
LOS FAILURE
Loss of Signal Failure
RECOVERY
loop is performing start-up process
T-FCP-15MIN
15-minute FCP Threshold Cross Alert
T-CVP-15MIN
15-minute CVP Threshold Cross Alert
T-ESP-15MIN
15-minute ESP Threshold Cross Alert
T-SESP-15MIN
15-minute SESP Threshold Cross Alert
T-SEFSP-15MIN
15-minute SEFSP Threshold Cross Alert
T-FCP-1DAY
1-day FCP Threshold Cross Alert
T-CVP-1DAY
1-day CVP Threshold Cross Alert
T-ESP-1DAY
1-day ESP Threshold Cross Alert
T-SESP-1DAY
1-day SESP Threshold Cross Alert
T-SEFSP-1DAY
1-day SEFSP Threshold Cross Alert
*Note
: Please refer to
Table 4-4
for HDSL
Performance Monitor Type Descriptions.
Содержание DT-2000 Series
Страница 6: ...CHAPTER 1 INTRODUCTION CONTENT 1 1 General Description 1 2 Specifications 1 3 Module List...
Страница 7: ......
Страница 14: ...CHAPTER2 Unit Description CONTENT 2 1 General Description 2 1 1 Desktop Units 2 1 2 Rack Mounted Units...
Страница 15: ......
Страница 26: ...UNIT DESCRIPTIONS 2 11 This page is intentionally left blank...
Страница 27: ......
Страница 29: ......
Страница 41: ...3 12 INSTALLATIONS This page is intentionally left blank...
Страница 42: ......
Страница 69: ...4 26 OPERATING MAINTENANCE This page is intentionally left blank...