Voltage loss (Volt-drop) of electronics without contact
resistances and internal resistance of the battery:
Voltage loss @ 10A: ca. 0.04V /
maxi
0.015V
Voltage loss @ 20A: ca. 0.08V /
maxi
0.030V
OPERATION
1. Install the evaporator WITH coil on the battery carrier first,
then insert the battery with the positive forward into the bat-
tery carrier and screw the battery firmly (no violence).
Caution: The electronic reverse polarity protection prevents damage
to the electronics ONLY! As far as possible, the mechanical reverse
polarity protection in the battery cover prevents uncontrolled vaporing
in reverse polarity. Due to the different, and future, battery types, there
is no guarantee for it! Anyway, use only the original battery cover!
2. The Vireo now performs a selftest and overload test. If the red LED
goes out, the device is ready. Otherwise please refer to the appen-
dix for eventual messages.
3. By pressing the button you supply the maximum possible power to
the evaporator that your battery allows because of your coil and its
charge level.
4. When you press the button, the green LED should light. From a
battery voltage of 3.0V, the red LED will pulse additionally (the lo-
wer the voltage, the faster the pulses) down to the cutoff voltage of
2.6V. Thereby you will be warned of the imminent replacement and
also of a possible deep discharge of the battery.
sKEYLOCK
You can activate an electronic key-lock by rapidly pressing of the but-
ton five times. This is indicated briefly by the red-lit LED!
The deactivation of the key-lock is done and signaled in the same way.
The key lock is used only for temporary deactivation of the
Taifun Vireo
Operation manual