© 2015 SmokerStore GmbH
Page: 24
If, in on-state or off-state, the permissible temperature of the MOSFET
is reached, this is indicated by a slow flashing red LED (approximately
1 x per second). Vaporing is not possible then. The device needs to
cool down until the flashing stops, before it is ready for use again!
While pressing the button (vaporing)
Okay:
s4HEGREEN,%$SHOULDLIGHTUPONLYWHENTHEDEVICEISREADYANDYOU
press the button! From 3.0V, the red LED will pulse additionally to the
green LED (the lower the voltage, the faster the pulses). At 2.6V the
green LED goes out and the red LED stays on for about 10 seconds
more, then the device shuts down completely! You need to insert a
new battery.
Error:
s4HEDEVICEDOESNOTSTARTTOVAPORANDTHEGREEN,%$WILLNOTLIGHT
up! The key lock is activated or the Vireo has been completely shut
down before due to low battery voltage or an error.
s4HERED,%$LIGHTSUPFORABOUTSECONDSANDTHENTHEDEVICE
shuts down completely! The minimum permissible battery voltage of
2.6 V was reached.
s&ASTmASHINGRED,%$FORABOUTSECONDSTHENNORMALLYCOMPLETE
shutdown! The overload protection has triggered, probably due to a
short circuit in the evaporator or moisture.
Without pressing the button (sleep)
Okay:
s.ODISPLAYNEITHERREDNORGREEN
Error:
s3UDDENLYTHERED,%$LIGHTSUPFORABOUTSECONDSANDTHENTHE
device shuts down completely!
The minimum permissible battery voltage of 2.6 V was reached.
s&AST mASHING RED ,%$ FOR ABOUT SECONDS UNTIL THE REMOVAL OF
Taifun Vireo
Operation manual