4.5.2 The operation of chairman unit
The chairman unit features the functions of a delegate
unit and in addition priority function:
If the priority mode is set as “All mute” in the main unit
configuration, all active conference units will be
muted when the priority button on the chairman unit is
pressed and return active when the priority button on
the chairman unit is released;
If the priority mode is set as “All off” in the main unit
configuration, all active conference units will be
turned off automatically when the priority button on
the chairman unit is pressed.
Note:
When there is more than one chairman unit in a
system and if one chairman is pressing the
priority key, the priority keys of the remaining
chairman units will be inoperable temporarily.