XT-1/XT Mini Manual
13-111 05, 2015-08-14
Page 25 of 32
5.1.1.2
AXIS A1001
Configure A1001 to use reader protocol Wiegand with "Dual LED" and set the card format to H10302.
GND
[READER I/O] -
IN1+
[READER I/O] 12V
CL/LOAD
N/C
IN1-
[READER I/O] IO5
D0/CLK
[READER DATA] D0
IN2+
[READER I/O] 12V
D1/DATA
[READER DATA] D1
IN2-
[READER I/O] IO4
S101 - Wiegand format: W37N/H10302
S301 - Vigilant pull-ups enabled
Tested version: Firmware version 1.30.0
5.1.1.3
Bewator Entro
Configure the Bewator Entro system to use H10302 format.
GND
0V
IN1+
N/C
CL/LOAD
N/C
IN1-
N/C
D0/CLK
D0/CLK
IN2+
N/C
D1/DATA
D1/DATA
IN2-
N/C
S101
S301 - Vigilant pull-ups disabled
Bewator Entro
≥
6.5:
Wiegand format:
W37N/H10302
Older versions:
Wiegand format:
W37R/H10302
Tested version: Bewator Entro 6.55.011
5.1.1.4
Bewator Omnis (with E2V)
The Vigilant reader behaves as a RB500 reader in Clock&Data mode.
GND
[Conn. G] -
IN1+
[Conn. G] +12V
CL/LOAD
[Conn. E] A
IN1-
[Conn. G] G
D0/CLK
[Conn. E] B
IN2+
[Conn. G] +12V
D1/DATA
[Conn. E] C
IN2-
[Conn. E] R
S101 - Magstripe format: M8N/H10320
S301 - Vigilant pull-ups enabled
Tested version: Bewator Omnis 6.0.107
1
8
ON
S101
1
8
ON
S301
1
8
ON
S301
1
8
ON
S101
1
8
ON
S101
1
8
ON
S101
1
8
ON
S301
Содержание XT Mini
Страница 1: ...XT 1 XT Mini Manual ...