Check all power connections
•
Turn master power supply switch - ON, for the 2000I-DP (page 7)
•
Turn master power supply switch - ON, for the HDIT-108R (page 8)
•
Turn on the power switch for the HDIT-108R (Figure 4).
Wait for drive lights to stop blinking.
•
Turn on the power switch for 2000I-DP (Figure 3)
•
Wait for 2000I-DP to initialize with the HDIT-108R
To correctly power-up the 2000I-DP, the following procedures must be
performed in the order listed below:
2000I-DP Power-Up Procedures
System Rear Panel - Power Supplies
Situated on the back of both the 2000I-DP and the HDIT-108R are Auto-
Switching 115/230VAC power supplies,
(See Figure 16).
FOr each system, the
system main power switch is located just beneath the power supply’s cooling fan.
Turn off the main power switch before servicing or moving the unit.
Power Supply Specifications
INPUT:
115/230VAC
60/50Hz
10/5A
OUTPUT: 300W (Total Combined MAX)
(+6V/+3.3V Total MAX 140W)
OUTPUT:
+5VDC @ 30A
+12VDC @ 14A
-5VDC @ 0.3A
-12VDC @ 1.0A
+3.3VDC @ 22A
+5VDC @ 0.2A
2
7
Figure 4
Figure 3
Power
Switch
Figure 16