Features

     

The 2000I-DP and the HDIT-108R, as all products in the HDIT product line,

are specifically designed to provide unsurpassed performance and reliability where
rack space is very limited. TAG’s R&D department have labored over countless CAD
drawings to fully utilize every square inch of space.  The 2000I-DP and the HDIT-
108R is comprised of the following features:

(2) 2U heavy-duty industrialized 90-mil. rack-mount server chassis (24”x19”x3.5”)

Locking slide rails

300W auto-switching power supply for 2000I-DP and HDIT-108R

2 high performance blowers for thermal dissipation across the HDIT chassis

Dual 1GHz. Pentium

®

 III processors each with 256KB high-performance cache

Genuine Intel

®

 motherboard featuring the Server Works Set III LE chipset

On-board SCSI controller

On-board 4MB SGRAM video adapter

Dual On-board 10/100 NIC’s

PCI RAID Controller with 16MB of RAID Cache

512MB 100MHz. SDRAM/ECC RAM, expandable to 2GB

(2) 2GB Ultra2 Wide SCSI LVD, hot-swap hard drives - 2000-I-DP

(4) 18GB Ultra-Wide SCSI, hot-swap hard drives - HDIT-108R

Internal SCSI PC Card Reader

48X E-IDE CD-ROM

SCSI Linking Cable

3.5” 1.44MB Floppy Drive

Microsoft NT Server 4.0

RAID Drive Rebuild

     

In the event that a hot-swap drive should fail, the HDIT-108R will still maintain

operation of the machine, but the machine is considered “critical”.  The HDIT-108R
will still function at full capacity, however the damaged drive should be replaced as
quickly as possible. Go to Page 4 for detailed instructions on the replacement of a
new hot-swap hard drive for the HDIT-108R. Once the failed drive has been replaced,
the 2000I-DP will automatically recognize and initialize the replacement drive.

Top Access Removal Instructions

     

When servicing the 2000I-DP or the HDIT-108R, disconnect the unit from the

power source, and remove the power cord 

(See Pages 10 & 11)

. All 22 

(See

Figure 20)

 screws need to be removed from the Top Access Panel to service the

unit.

Note: The two screws are located on the Front Panel of the 2000I-DP.
Failure to remove those will result in damaging the Top Access Panel.

The 2000I-DP or the HDIT-108R should never be serviced without contacting
TAG’s Tactical Technical Support Team first.

9

Figure 20

Содержание HDIT-2000I-DP

Страница 1: ...Reference Manual 22355 TAG WAY Dulles VA 20166 9310 Technical Support 877 TAG TECH 1 703 406 4516 tag com HDIT 2000I DP HDIT 108R ...

Страница 2: ...the NT 4 0 Server CD in the Drive 4 Change the boot priority in CMOS so that the CD ROM is now the primary boot device 5 When NT 4 0 Server begins to load press the F6 key 6 Type S and load the MegaRAID drivers for the RAID card 7 After drivers have loaded hit Enter 8 On the 1st Setup screen hit Enter 9 Type S and load the Adaptec 7800 Ver3 02 drivers for NT When prompted select the U2 drivers for...

Страница 3: ... High Density Information Technology and the TAG Ball graphic are trademarks or registered trademarks of Technology Advancement Group Inc This manual and or its contents may not be duplicated without written permission of Technol ogy Advancement Group Inc Printed in the USA 10 The The 2000I DP and the HDIT 108R features several SCSI devices each with its own unique SCSI ID See Figures 21 22 The fo...

Страница 4: ...tra Wide SCSI hot swap hard drives HDIT 108R Internal SCSI PC Card Reader 48X E IDE CD ROM SCSI Linking Cable 3 5 1 44MB Floppy Drive Microsoft NT Server 4 0 RAID Drive Rebuild In the event that a hot swap drive should fail the HDIT 108R will still maintain operation of the machine but the machine is considered critical The HDIT 108R will still function at full capacity however the damaged drive s...

Страница 5: ...d 512MB of RAM makes this low profile server a powerful one It is equipped with a DAT backup device a ZIP Drive LS 120 Drive Floppy Drive CD ROM and a PC Card Reader All devices are easily accessable from the front panel Connecting HDIT 108R to the 2000I DP The 2000I DP is connected to the HDIT 108R by the external SCSI connec tor See Figure 19 The server connects to the left SCSI RAID connector W...

Страница 6: ...erformed in the order listed below 2000I DP Power Up Procedures System Rear Panel Power Supplies Situated on the back of both the 2000I DP and the HDIT 108R are Auto Switching 115 230VAC power supplies See Figure 16 FOr each system the system main power switch is located just beneath the power supply s cooling fan Turn off the main power switch before servicing or moving the unit Power Supply Spec...

Страница 7: ... turnsoff A slot is accessed in which no card is inserted The red LED remains lit until the card in the other slot is accessed A card is inserted but it cannot be accessed by the PC Card reader This error can have various causes for example the unit is attempting to write data to a write protected a read only or an unknown I O card or a hardware error exists on the card The amber LEDs on the right...

Страница 8: ...e top left drive Drive 2 is SCSI ID 1 the bottom right drive Drive 3 is SCSI ID 2 and the top right drive Drive 4 is SCSI ID 3 Refer to page 10 for all SCSI IDs In the event that one drive should fail simply remove it and replace it with a working drive To remove either drive insert the hard drive module key and turn the keylock to the unlocked position Grab the handle and slide the drive out Inse...

Отзывы: