Controller Configuration

 

 
“More”

 takes the operator to 

“Controller Configuration”.

 

 

 

“Drill”

 

button takes the operator to the “Drill Settings” screen. This screen is only active in 

the “Stopped” mode and should only be altered when the operator is changing from one 
machine to another and in contact with either their 

Taege Dealer or Taege Engineering Ltd 

technical person.  
 

Some controllers require a 

"password" 

to access this screen. 

 

“Inputs”

 shows where the controller is configur

ed to accept “High impedance”, “PNP” and 

“NPN” type sensors. 

Содержание RC350

Страница 1: ...reaking Company Since 1923 RC350 Controller Rev 01 05 Manufactured by Dealer Local Agent Taege Engineering Ltd Main West Road Sheffield 7500 New Zealand Ph 64 3 318 3824 Fax 64 3 318 3646 E mail sales taege com www taege com ...

Страница 2: ...ny Since 1923 Contents Page Introduction 3 Starting the Controller 4 Quick Calibration 5 Calibration Check 6 Operating the Controller 7 Additional Tasks 8 Controller Configuration 9 Glossary 10 Warning Screens 11 Disclaimer 11 Warning 11 ...

Страница 3: ...anual using service maintenance etc the life span and the second hand value of the machine can be extended If you ever lend or sell this machine make sure that the borrower or buyer gets the operator s manual so they will also know how to properly maintain and use it You can download additional copies of your owner s manual from www dealer taege com Please quote your controller version when seekin...

Страница 4: ...made press the Cancel button but if it is correct press OK The last weight entry is always shown above the OK button Was xxx x kg ha Selecting the Crop When you press the Select Crop button a crop list shows for that hopper 1 Front Select the crop and if you wish press Edit and name the crop and enter the target weight At any stage you can Cancel and stay with the original name and setting or Save...

Страница 5: ...re all rollers are dispensing seed then empty the calibration tray 3 Press the Calibrate button You will see the seed collecting in the calibration tray and the sample bar on the controller counting down 4 Weigh the product collected using the scales 5 Press Weight and enter the weight of the sample in grams 6 Press Ok 7 Press Accept if correct 8 Enter the sowing rate by pressing kg ha or by press...

Страница 6: ...travel until the ha on the controller records 0 010 ha on screen and then stop the wheel 10 Weigh the amount of product this should equal about 100th of the target seeding weight kg ha If it is within 10 use the button to increase decrease the target seeding rate Then check the weight again but if there is more than a 10 difference Recalibrate If you are testing a double hopper system you may want...

Страница 7: ... the machine is operating and in the ground a speed indicator will move across the screen between the hopper select buttons and and the Kph speed dial The weight being applied can be altered while operating by selecting the correct hopper and pressing either the or buttons or by selecting the kg ha button to make the change This change does not happen until the OK button is pressed The Indicator b...

Страница 8: ...perator the actual settings for the machine No changes can be made on this screen The left hand side of the screen shows the machine Configuration Settings and on the right hand side the information about the selected hopper Press the or buttons to go to another hopper When you have completed this task press the Back button Area Reset when selected shows No which reverts to the Menu screen and Yes...

Страница 9: ...screen This screen is only active in the Stopped mode and should only be altered when the operator is changing from one machine to another and in contact with either their Taege Dealer or Taege Engineering Ltd technical person Some controllers require a password to access this screen Inputs shows where the controller is configured to accept High impedance PNP and NPN type sensors ...

Страница 10: ...count Pulses over given distance Wheel Input Diagnostic Test And verification Front Diagnostic Test and Verification Information on a motors performance Off Off not operating On ON machine or test in operating mode Err Deviation from a given point Cnt Count Volts Vdc Set RPM Nominate an RPM Factory Reset Go back to factory settings Restart Full restart of controller Debug Identifier for Tech only ...

Страница 11: ...lication and should only be accessed when a Dealer or Taege technical person has been contacted Disclaimer The information in these instruction sheets may or may not apply to your controller In using this information you acknowledge that such information and materials may contain inaccuracies or errors and we expressly exclude liability for any such inaccuracies or errors to the fullest extent per...