Quick Calibration
Plug in the RC350 Controller and make sure that the power supply to the machine is
connected.
1. Choose the hopper you wish to calibrate by using
"<"
or
">"
.
2. Move the collector tray and place the calibration tray under the sponge rollers and
press
"Prime"
and make sure all rollers are dispensing seed , then empty the
calibration tray.
3. Press the
"Calibrate"
button. You will see the seed collecting in the calibration tray and
the sample bar on the controller counting down.
4. Weigh the product collected using the scales
5. Press
"Weight"
and enter the weight of the sample in grams.
6. Press
"Ok"
7. Press
"Accept"
if correct
8. Enter the sowing rate by pressing
"kg/ha"
or by pressing the
"+"
or
"-"
If fitted select any of the other hopper/s and go to 1. and follow the procedure.
Press
"GO"
You are now ready to drill.