System Components – tado° Extension Box

tado° Extension Box

The tado° Extension Box acts as a communication link 
between the tado° Smart Thermostat and the boiler. It 
replaces extenal controllers, external receivers or is direct-
ly connected to the boiler.

The Extension Box is powered by 230V mains connection 
for relays and by low voltage power supply when connected 
to analog or digital interfaces. For potential free relay wiring, 
an additional two wire power supply cable maybe required 
which is provided by tado° upon request.

Wiring

tado°’s Extension Box has both 230V and a low voltage interfaces. Two relay wiring 
configurations are possible and are distinguished by two different jumper positions. 
The first wiring option is a potential free wiring connection, where the power supply is 
separated from the relays. This wiring option is to connect low voltage single relays.
In case a UK standard backplate is present and wired as a 230V dual relay (central 
heating and hot water) the tado° Extension Box can simply be mounted on the existing 
backplate and does not require any rewiring. 
For UK standard backplate where only one relay is wired, some rewiring might be 
required such that the wires correspond to tado°s “Relay Wiring 1” as indicated at the 
back of the Extension Box.

Relay Wiring 1

Potential Free

Relay Wiring 2

Switched Live

1

 

2

NL

12

34

COM NC

NO

A

NL

12

34

A

HW

OFF

CH

OFF

HW

ON

CH

ON

TROUBLESHOOTING: 

The tado° Extension Box can be reset by pressing the button on 

top for more than 8 seconds. After a reset, the box will start to look for a connection to the 

tado° bridge and the LED will blink during that process. 

tado° Installation

tado° provides installation instructions specific to every heating setup. Those 
instructions are provided as online webflow. This documentation at hand is no 
replacement of these instructions and is a documentation of tado° devices and 
features, not of the installation process itself.

WARNING: 

While the self installation of the tado° system is possible, tado° strongly 

recommends booking of a professional installation by one of our tado° installation profes-

sionals.

i

Содержание RU01

Страница 1: ...Technical Documentation V1 0 tado Smart Thermostat tado Extension Box tado Additional Thermostat ENGLISH...

Страница 2: ...0 2 Product Overview Compatibility Model Predictive Control Mobile and Web App UI Smart Thermostat UI System Components tado Bridge tado Smart Thermostat tado Extension Box Support Technical Specifica...

Страница 3: ...ut a room thermostat the Extension Box acts as a reciever the Smart Thermostat as a wireless sensor and remote control Controls heating based on sensor data from the tado Smart Thermostat Typically in...

Страница 4: ...heating systems including combi system and heat only boilers conventional and condensing boilers common Y S and W plan setups hydronic underfloor systems electric underfloor systems with a maximum sw...

Страница 5: ...r the algorithms which automatically adjust the heating output to the user s needs A building model is automatically created for each household to enable tado s proprie tary model predictive control t...

Страница 6: ...er when you are at home Schedule When set to Schedule tado prepares hot water according to the settings in the dedicated hot water schedule It can be set in the web application Manual When set to manu...

Страница 7: ...n After pressing the button once more the setpoint temperature is displayed and can be adjusted using the cap touch buttons which light up when settings can be changed On heating systems that support...

Страница 8: ...ration ON Hot water Off Hot Water Auto Operation HEATING HOT WATER not supported by all heating systems Operation Mode press twice Change Settings press three times State press once State press four t...

Страница 9: ...s internet light continues to flash check the ether net cable and or reset the device by unplugging and plugging the power cable back in If the Bridge is still unable to connect there may be an issue...

Страница 10: ...t does not replace an existing wired thermostat it can be placed in any appropriate location When installing the Smart Thermostat please observe the following points place the Smart Thermostat in a lo...

Страница 11: ...thermostat use the three low voltage terminals on the right hand side The analog output is connected to A ground GND to and the positive input Vcc to When replacing a two wired digital thermostat the...

Страница 12: ...V dual relay central heating and hot water the tado Extension Box can simply be mounted on the existing backplate and does not require any rewiring For UK standard backplate where only one relay is wi...

Страница 13: ...30V DC 6 4 A Radio 868 MHz Mesh 6LoWPAN Display 10 x 19 LEDs 32 x 20 mm Material PC ABS Button 1x Mechanical 2x Capacitive Touch Colour white flat CE RoHS tado Extension Box Model BU01 Dimensions cir...

Отзывы: