background image

18

Customer Service Toll Free

833.382.2845 (833.3

TACTILE

)

2 .   Configure your garment(s) using the zipper configuration 

indicated on your Prescribed Treatment Card . Zip the appropriate 
pull string color (teal or black) to the numbered zipper (#1 or #2) . 
Use the colored zipper to start the zipper . The following zipper 
configurations are available: 
•  Black pull string to zipper #1 – Petite 
•  Black pull string to zipper #2 – Small 
•  Teal pull string to zipper #1 – Medium 
•  Teal pull string to zipper #2 – Large

3 .  Zip the garment up completely .

Garment Application:
4 .  Slide your arm into the garment .

 

NOTE: 

If the suggested configuration is too tight or too loose, try 

another configuration based on the listings above. 

5 .  Pull the arm garment up over your shoulder making sure  

your fingertips remain fully enclosed in the garment . The zipper 
should align with the top of your shoulder . 

Figure 4.2.a: 

Preparing the 

Arm Garment

Figure 4.2.c: 

Fully Applied 

Arm Garment

Figure 4.2.b: 

Slide the Arm  

Garment On

Содержание ENTRE PD08-U

Страница 1: ...M O D E L P D 0 8 U U S E R G U I D E User Guide...

Страница 2: ...eating the Upper Extremity 10 Chapter 3 Controller Unit Set Up 11 3 1 Setting Up the Controller Unit 11 3 2 Connecting the Hose to the Controller Unit 12 Chapter 4 Garment Application 15 4 1 Applying...

Страница 3: ...7 1 Limited Warranty and Service for Home Use 28 7 2 Limited Warranty and Service for Facility Use 29 7 3 Return Policy 29 7 4 Equipment Lifetime 29 Chapter 8 Technical Information 30 8 1 Technical In...

Страница 4: ...ou manage your condition improve your health and allow you to enjoy a better quality of life This guide provides the information needed to set up and use your Entre system 1 1 How to Contact Tactile M...

Страница 5: ...ent Use this product only at the settings prescribed by your healthcare provider Do NOT Dispose With General Household Waste Tactile Medical complies with the Waste Electric and Electronic Equipment D...

Страница 6: ...t attempt to service the controller unit Such attempts could result in injury or damage to the product and will void any warranty Do not disassemble the controller unit Unplug the controller unit when...

Страница 7: ...on openings on the back or the sides of the controller unit Keep the ventilation openings free of debris such as lint and hair Never operate the controller unit on a soft surface such as a bed couch o...

Страница 8: ...ent but not yet in remission Any circumstance where increased lymphatic or venous return is undesirable 1 5 Unpacking Instructions When your Entre system arrives it is important that you carefully unp...

Страница 9: ...y is ordered Extender provided only if ordered Upper Extremity Treatment The garments and device accessory needed for upper extremity treatment may include the following Arm garment Y connector provid...

Страница 10: ...ose connector which is attached to the garment Depending on the prescription from your physician a Y connector can be added to allow two garments to be used at the same time The device applies differe...

Страница 11: ...treatment you will receive a Y connector accessory 2 2 Adjustable Pressure Levels Your healthcare provider will determine what pressure setting s are appropriate for you The Entre controller unit all...

Страница 12: ...tinuous motion Full Leg Treatment This option provides full leg treatment in a distal to proximal foot to top of thigh direction via the sequential inflation of the 8 chambers Treatment time 60 minute...

Страница 13: ...emity Full Arm Treatment This option provides full arm treatment in a distal to proximal hand to top of biceps direction via the sequential inflation of the 8 chambers Treatment time 60 minutes Figure...

Страница 14: ...surface near an electrical outlet Position the device so you have easy access to the plug 2 Plug the supplied power adapter into the power adapter inlet on the back of the controller unit Then plug th...

Страница 15: ...must be connected to the controller unit prior to connecting your garments NOTE Both garments must be connected to the Y connector Figure 3 2 a Hose Connector BOTTOM Tab Connector Collar Arrowed Latch...

Страница 16: ...row is facing up Figure 3 2 b Figure 3 2 b Connecting the Hose to the Controller Unit 2 Align the arrowed latch with the notch on the controller unit port 3 Reposition your hand so your thumb and fing...

Страница 17: ...onnected Two clicks will be heard one for the top and one for the bottom latch Figure 3 2 d Figure 3 2 d Properly Connecting the Latches 5 If using the Y connector ensure the Y connector is attached t...

Страница 18: ...clothing example scrubs stockinette If skin irritation develops consult with your doctor Lymph fluid is moved through the vessels in the skin It is important to avoid wearing anything during therapy t...

Страница 19: ...le Black pull string to zipper 1 Petite Black pull string to zipper 2 Small Teal pull string to zipper 1 Medium Teal pull string to zipper 2 Large NOTE If you are using an extender position it so the...

Страница 20: ...tment Figure 4 1 b Figure 4 1 b Fully Applied Full Leg or Half Leg Garment 4 2 Applying the Arm Garment Garment Preparation 1 Once the garment is connected to the controller unit unfold and place the...

Страница 21: ...l string to zipper 2 Small Teal pull string to zipper 1 Medium Teal pull string to zipper 2 Large 3 Zip the garment up completely Garment Application 4 Slide your arm into the garment NOTE If the sugg...

Страница 22: ...to be modified from one treatment to the next 1 Turn the controller unit ON Turn on the controller unit by pressing the ON OFF button located on the front panel Figure 5 1 a The ON OFF button and PRE...

Страница 23: ...in a chair or bend your affected limb s during the therapy session 3 Elevate the affected limb s on a pillow just above your hips 4 Check your pressure setting to ensure you have selected the correct...

Страница 24: ...ug the device This will cause the internal valves to close and the garment s will not deflate properly 5 5 Storing the Entre System To store the Entre system follow the steps outlined below 1 Unplug t...

Страница 25: ...ector are to be cleaned as needed using a damp cloth and mild household cleaner 1 Unplug the power adapter from the electrical outlet 2 Wipe all accessible surfaces including the power adapter 3 After...

Страница 26: ...pray or similar disinfectant compliant with OSHA s Bloodborne Pathogen Standard 29 CFR 1910 1030 and or registered with EPA To disinfect the PD08 U system including garments controller or accessories...

Страница 27: ...able disconnect the garment from the controller unit and then reconnect again Power up the device by pressing the ON OFF button Restart the therapy session by pressing the START PAUSE button Ensure t...

Страница 28: ...troller unit and then reconnect again Power up the device by pressing the ON OFF button Restart the therapy session by pressing the START PAUSE button 2 Please call Customer Service if unable to resol...

Страница 29: ...per and lower connector latches are engaged 5 If the chambers still do not fill turn the machine off detach the connectors and turn the machine ON again 6 Feel for air coming out of the controller uni...

Страница 30: ...s not function 1 Power down the device Power up the device by pressing the ON OFF button 2 Please call Customer Service toll free for instructions The controller unit makes an abnormal noise 1 Stop th...

Страница 31: ...ts regarding suitability for use or performance of the Entre system shall be deemed to be a warranty or representation by Tactile Medical for any purpose nor give rise to any liability or obligation o...

Страница 32: ...vince or country 7 2 Limited Warranty and Service for Facility Use Contact Tactile Medical for information regarding the service agreements available to facilities 7 3 Return Policy Returns are not ac...

Страница 33: ...ural rubber latex Therapy Programs 1 Chambers 8 Mode of Operation Continuous Calibration Recalibration not required Electromagnetic Interference EMI Electromagnetic Compatibility EMC The Entre system...

Страница 34: ...ve 2002 95 EC Table 7 Guidance and Manufacturer s Declaration Electromagnetic Emissions The Entre system is intended for use in the electromagnetic environment specified below The customer or the user...

Страница 35: ...typical commercial or hospital environment Surge IEC 61000 4 5 1 kV line to line 2 kV line to earth 1 kV line to line 2 kV line to earth Voltage dips short interruptions and voltage variations on powe...

Страница 36: ...rom fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked wi...

Страница 37: ...ce facing away from you at eye level at a distance that maximizes character clarity generally 20 inches 50 cm to 40 inches 100 cm with an illumination of 500 lx minimum Call Tactile Medical Customer S...

Страница 38: ...35 This page has intentionally been left blank...

Страница 39: ...36 Customer Service Toll Free 833 382 2845 833 3TACTILE This page has intentionally been left blank...

Страница 40: ...s MN 55416 USA T 612 355 5100 F 612 355 5101 Customer Service Toll Free Tel 833 382 2845 833 3TACTILE Toll Free Fax 866 435 3949 Hours 7 a m to 7 p m CT Monday Friday tactilemedical com For Additional...

Отзывы: